18—
-EVE Power CO,LTD Confidential Proprietary-
Maximum
continuous
charging power
Charge to 3.65V with a constant power of 448W
448W3.65V
Standard
charging
temperature
Absolute charging
temperature (cell
temperature)
()
No matter what charging mode the cell is in,once
the cell temperature exceeds the absolute
charging temperature range,stop charging.
No matter what charging mode the cell is in,once
the cell voltage exceeds the absolute charging
voltage,stop charging.
Note:In order to ensure the safe use during the whole life cycle and maximize the service life of
the cell,the charging power (rate)must be adjusted according to the SOH (capacity attenuation)of
the cell.It should be ensured that the BMS has this function to monitor the actual charging power
(and allowable charging power limit),and trigger fault and protection functions when necessary.
4.2.2 Other Charging Modes
4.2.2.1 Continuous charging modes