23
-EVE Power CO.,LTD Confidential Proprietary-
Model
LF280K
Specification No
PBRI-LF280K-D06-01
Version
C
Recommended
Operating
Temperature
Range
10℃~45
Recommended cell using temperature
range
Maximum operating
temperature
60℃
If the cell temperature exceeds the maximum
operating
temperature,the cell power needs to be reduced to 0
Minimum operating
temperature
-30°℃
If the cell temperature exceeds the minimum
operating
temperature,the cell power needs to be reduced to 0.
Maximum safe
temperature
65℃
If the battery temperature exceeds the maximum
safe temperature,it will cause irreversible and permanent
damage to the battery,and the usershould not use it higher
than the
maximum safe temperature.
Minimum safe
temperature
-35
If the battery temperature exceeds the minimum
safe temperature,it will cause irreversible and permanent
damage to the battery,and the user should not lower the
minimum
safe temperature when using it.
Notes :
a)Prohibit charging the cell at low temperatures (lower than 0℃)and the minimum safety
temperature specified by this specification,otherwise EVE will not be responsible for any quality
assurance liability.
b)The heat dissipation design of pack may effect cell electrical performances,EVE will not
be responsible for any liability regarding cell quality issues caused by the heat dissipation design.