Choosing a location for Eve Smoke
Install Eve Smoke in rooms posing a fire risk (living room with fireplace, kids‘ rooms, loft/cellar
extensions, etc.):
Preferably centrally on the ceiling
Away from ventilation outlets that may channel smoke away
Over 50 cm away from any obstacles (walls, partitions, joists, or similar)
For hallways over 10 m in length, install an alarm at both ends
If you cannot install Eve Smoke horizontally on the ceiling, install it:
Over 50 cm below the ceiling and over 50 cm away from corners of the room
Away from any sources of electrical interference (electricity meters, metal cupboards, etc.)
If installing on a metallic wall, drywall construction, or ducting: mount Eve Smoke on a non-metallic base
(wood or plastic) and away from any potential sources of electrical interference (electricity meters, metal
casings, fluorescent lights, etc.)
Minimum protection: for each floor, install one
smoke alarm in the hallway or landing, as well as one
in each bedroom and kid‘s room.
Extra protection: Install one smoke alarm in the
kitchen provided that the smoke alarm function is
disabled (see Chapter 2).
Maximum protection: Install additional smoke
alarms in the living room, hobby room, laundry
room, attic, and cellar.
Avoid installing Eve Smoke:
Directly on a metallic surface
Close (< 50 cm) to low voltage transformers, energy saving bulbs, electronic ballasts
In very dusty areas
In rooms where the temperature is lower than -10°C or higher than +55 °C, as these temperatures may
compromise the performance of the smoke alarm
Less than 1 m away from warm air, air conditioning, or ventilation outlets, as these may dissipate smoke
Less than 6 m away from a fireplace or a wood-burning stove, as the smoke emitted via combustion may
trigger unnecessary alarms
In rooms where alarms may be unnecessarily triggered as a result of cooking or steaming
In damp rooms or rooms susceptible to the formation of condensation (bathrooms, laundry rooms, etc.)
At the uppermost point of vaulted ceilings, where an air pocket may form and prevent smoke from reaching
Eve Smoke
≥ 50 cm ≥ 50 cm
Ideal location
Alternative location for
mounting on a sloped ceiling
Alternative
location if ceiling
mounting is not
possible
40 cm (min) - 50 cm (max)
Observe building regulations.
4