EasyManua.ls Logo

Everflo EFSW2200 - User Manual

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
EFSW-MANUAL
Owner’s Manual
Instructions for Assembly, Testing, Operation, Servicing, and Storage
Bleach Pump with Motor Shield: For use with bleach**
WARNING
READ and UNDERSTAND the Owner’s Manual completely before using this pump.
Assemble, test, and use only in accordance with the Owner’s Manual instructions.
EXERCISE CAUTION when mixing chemicals, as incorrect ratios or mixtures could
release harmful gases.
READ and FOLLOW chemical safety instructions.
KNOW emergency procedures BEFORE handling chemicals. Pump leaks, bodily chemical
contact, poisoning, and spills require immediate response.
AVOID inhaling, ingesting, or coming into contact with any chemicals.
WEAR personal protective gear when operating, cleaning, and servicing the pump.
KEEP pump and spray materials away from children and pets. Some chemicals are
especially toxic to them.
DO NOT TURN ON POWER to pump until ready to spray in order to avoid unintentional
spray release.
SOAK vegetation well in the area surrounding the work zone prior to and after spraying
bleach. Bleach can kill vegetation if not soaked thoroughly.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
Improper use of the pump or handling of chemicals could result in serious injury, illness
to the operator or nearby persons/animals, or could cause damage to the environment.
**This pump is recommended for use in spraying bleach. The pump will be damaged, and warranty
voided if used to apply any petroleum-based product (gasoline, diesel, kerosene, or oil). The pump
should not be used to transfer any product intended for human consumption. WE RECOMMEND
THAT THE PUMP NOT BE USED FOR OTHER PURPOSES ONCE IT HAS BEEN USED FOR
SPRAYING BLEACH. Any chemical will leave some residual in the pump components, even after
the pump has been properly cleaned. These residual chemicals can have unexpected effects on future
uses. This pump should not be used by people with reduced physical, sensory, or mental capabilities
or by those who lack experience or knowledge of product use.
Any Questions, Comments, Problems, or Parts Orders
Call Everflo Product Support at 1-800-864-1649
ITEM NUMBER: EFSW2200,
EFSW4000,EFSW5500
SERIAL NUMBER: __________

Questions and Answers

  • A
    Angela RiveraJul 29, 2025
    How to fix Everflo Water Pump that will not turn on?
    • P
      Paul HensonJul 29, 2025
      If your Everflo Water Pump won't turn on, several factors could be at play. Start by checking the battery connections to ensure they are secure. Inspect the wires for any signs of shorts. Replace the fuse if it has blown. A faulty pressure switch might also be the culprit, requiring replacement of the pressure switch assembly. Finally, verify that the voltage is within the correct range (±10%).
  • M
    mpittmanAug 2, 2025
    Why is my Everflo EFSW2200 having low pressure/flow?
    • M
      Maria FosterAug 2, 2025
      If you're experiencing low pressure or flow with your Everflo Water Pump, begin by checking for inlet air leaks and tighten any loose fittings or replace cracked fittings. Restrictions in the inlet or outlet tubes can also cause this issue, so remove any obstructions. Verify the voltage is correct (±10%). Additionally, inspect for clogged components such as intake valves, the inlet strainer, or the intake tube, and remove any obstructions. Replacing the pump cartridge may be necessary if the diaphragm or valves are worn.
  • M
    michaelsandersAug 8, 2025
    What to do if Everflo EFSW2200 cycles while not spraying?
    • C
      Clarence PageAug 8, 2025
      If your Everflo Water Pump cycles even when it's not spraying, there might be a leak in the system. Try tightening any leaking hose clamps or fittings. A faulty pressure switch can also cause this, so consider replacing the pressure switch assembly. Ensure the voltage is correct (±10%). Trapped air within the system can also lead to cycling, so purge the air from the system.
  • H
    hollowaybridgetAug 13, 2025
    Why is my Everflo EFSW2200 leaking?
    • R
      Robin JonesAug 13, 2025
      If your Everflo Water Pump is leaking, start by tightening any loose fasteners. If the pump seals are degraded, consider replacing the pump cartridge.
  • J
    Jeffrey PierceAug 18, 2025
    How to fix rough operation of Everflo EFSW2200 Water Pump?
    • K
      Kevin BeckerAug 18, 2025
      If your Everflo Water Pump is operating roughly, ensure it's mounted on a rigid surface, as a flexible mounting surface can cause this issue. Tighten any loose pump cartridge fasteners. Decompress the base feet, and ensure the pump is plumbed with flexible plumbing, not rigid plumbing.
  • E
    Eric GoldenAug 23, 2025
    What to do if Everflo Water Pump will not turn on and LED light is on?
    • B
      Brandon OwenAug 23, 2025
      If your Everflo Water Pump will not turn on but the LED light is on, this indicates a leak inside the pump cartridge. You should replace the pump cartridge.

Summary

Hazard Signal Word Definitions

Intended Use

Summary of Important Information

Warning Label Location

Installation

Step One: Mounting

Details the process of securely attaching the pump in its designated horizontal mounting position.

Step Two: Plumbing

Guides on connecting hoses and tubing to the pump's quick connect ports.

Features

Operation - Important Safety Information

Operation - Preparing the Pump for Each Use

Operation - Using the Pump

Step One: Assess wind conditions and clear work area.

Evaluates weather and work area safety, including wind speed and clearing bystanders/pets.

Step Two: Operate the pump.

Details the procedure for safely turning on the pump and managing its operation.

Step Three: Clean pump and decontaminate after use.

Storage

Preparing for storage

Instructions for winterizing or long-term storage, including flushing and adding antifreeze.

Removing from storage

Procedure to prepare the pump for use after it has been stored, including draining and flushing.

Troubleshooting

Maintenance

Specifications

Accessories

Exploded View - EFSW2200 - Rev A.2

Exploded View - EFSW4000 & EFSW5500 - Rev A.2

Limited Warranty

Everflo EFSW2200 Specifications

General IconGeneral
BrandEverflo
ModelEFSW2200
CategoryWater Pump
LanguageEnglish

Related product manuals