Troubleshooting (continued)
Bad electrical connection
Check battery connections
Replace pressure switch assembly
Pump will not turn on
and LED light is on
Leak inside pump cartridge
Tighten fittings
Replace cracked fittings
Inlet/ Outlet tube restriction
Tighten fittings
Replace cracked fittings
Inlet/Outlet tube restriction
Pump cycles while not
spraying
Tighten leaking hose clamps/fittings
Replace pressure switch assembly
Purge the air from the system
Flexible mounting surface
Mount pump on rigid surface
Plumb pump with flexible plumbing