present illumination. If the environment and the light source are changed,
you need to adjust the white balance again.
Ö MANUAL: The manual adjustment mode enables a more precise adjustment.
Please select ATW or AWC first. Then change to manual adjustment mode
and press the SET button. Set the suitable color temperature, and increase or
decrease the red and blue color values at the same time while checking the
color changes of the object.
SETUP
LENS DC <┘
SHUTTER ___
> WHITE BAL. MANUAL <┘
BACKLIGHT OFF
AGC MIDDLE
DNR LOW
SENS-UP AUTO <┘
SPECIAL <┘
EXIT
WHITE BAL.
RED |+++++++++| 32
BLUE |+++++++++| 39
N
ote: Under the following conditions, the WHITE BALANCE function may not
operate well. In such cases, please select the AWC mode.
1. When the object’s surroundings have a high color temperature.
2. When the object’s surroundings are dark.
3. If the camera faces a fluorescent light directly or is installed in a place where
the illumination changes constantly, the WHITE BALANCE function may become
unstable.