46 01-2018 5035 01
tacHo valuE limit
Sets the height of the upper piston in the
chamber during the low pressure infusion
(fresh brew).
The default value is 430.
If a value lower than the default
value is set, this can lead to hot water
escaping from the brewing unit.
prE-iNfusioN DosE
Sets the amount of water to be used during
the pre-infusion.
prE-iNfusioN timE
Sets the pre-infusion time before the actual
infusion occurs.
currENt profilE
Sets 3 pressure proles for the espresso
infusion:
-High
-Medium
-Low
When using the low setting, the low pres-
sure infusion parameters are displayed
(see the fresh brew parameters).
aDvaNcED iNstaNt paramEtErs
start
DElay
Sets an ingredient time delay; the delay is
useful if a recipe which consists of multiple
ingredients is created.
For example, when creating the "Hot choc-
olate with milk" recipe, a time delay can be
set between when the powder and the milk
is dispensed.
It can help the beverage be presented bet-
ter.
mixEr DElay
Sets a start delay time for the mixer, com-
pared to when the water is dispensed.
absolutE mixEr mix timE
The mixing duration can be set indepen-
dently from the pump/ valve operation time.
The mixing duration is set in milliseconds
and calculated from the moment the pump/
solenoid valve is activated.
rElativE mixEr timE
The mixing duration can be set dierently,
by stopping it before or after the pump/ so-
lenoid valve stops.
The mixing duration is set in milliseconds
and calculated from the moment the pump/
valve is activated.
mixiNg spEED (low / mEDium / HigH)
The mixing speed can be dened accord-
ing to the desired presentation of the prod-
uct.
watEr quEuE
Extends the amount of water dispensed
into the mixer after the mixing stage has
nished, in order to adequately rinse the
mixer.
Set the desired amount of water.