AirKey system manual version 2.7 |
06/03/2024 | Subject to technical changes and misprints
> In a last step, update the cylinder using your smartphone or coding station to
transfer the most recent event log entries to the AirKey Online Administration.
> Check the cylinder operates correctly by attempting to unlock it before you once
again close the door.
On the basis of physical battery properties, you must replace batteries at an
earlier stage and monitor the battery states and cylinder functions in low
temperatures (below -10 °C) over a prolonged period of time.
If the component indicates a communication fault after having replaced the
batteries, this is caused by the thumb turn attempting to communicate with
the electronics module. This does not work if the thumb turn has been
screwed to the electronics module.
Check locking components’ battery status using smartphones with mainte-
nance authorisation by updating the locking component and then viewing
the component details.
If you are unable to replace batteries in due time, there is the option to open the locking
component using the optionally available emergency power device.
Please refer to the Emergency power device section for a more detailed description.
After having operated a locking component using an emergency power
device, replace the batteries before once again closing the door.
After use carefully re-seal the white rubber cover featuring the EVVA logo to
continue to protect the emergency power device connector from penetrating
dust and humidity. For this purpose, do not use pointed objects to prevent
damage.
8.8 Repair options
Locking components’ repair options enable reactions to locking component faults. There is
the option to issue replacement locking components within the access control system or
remove a faulty locking component from the access control system.
8.8.1 Issuing and installing replacement locking components
Issuing and subsequently installing replacement locking components to replace existing,
faulty locking components with locking components in factory state. As a result, all
properties and authorisations for this locking component within the access control system
are maintained. After this process, the replacement locking component is no longer in
factory state.
> On the Home screen, select the Cylinders or Wall readers tile.
> Alternatively, select Access control system → Locking components in the main
menu.
> Click the locking component you would like to edit in the overview.