The component you would like to replace remains available for updates until
the replacement locking component has been completely installed. This
guarantees the event logs are complete for the case that there are access
events between installing the replacement component and successfully
completing replacement component installation.
When replacing locking components by Bluetooth the replaced component
and the replacement locking component are shown on the list of Bluetooth
components in range. De-energise the replaced component after having
replaced it. Only then will it no longer appear on the Bluetooth components
list.
> Establishing a connection using NFC (for Android smartphones): Tap the Connect to
component icon and hold the smartphone to the locking component in factory state.
> Establishing a connection using Bluetooth (for Android smartphones): open the
context menu of the locking component in factory state which you would like to add
to the access control system (⋮) and then select Connect.
> Establishing a connection using Bluetooth (for iPhones): Swipe the "In factory
state" designation of the locking component in factory state which you would like to
add to your access control system towards the left and then select Connect.
> After having updated, click Issue replacement cylinder in the locking component
details.
> In the following dialogue, select the locking component you would like to replace and
click Continue.
> If you are using NFC, once again hold the smartphone to the locking component in
factory state. If you are using Bluetooth, select the locking component in factory
state from the list of locking components in range.
> Specify whether you would like to add a maintenance tasks for later installation.
> Click Install later to cancel the process, providing you must still install the locking
component at the door or select Complete if the component has already been
installed at the door.
> Update the locking component after having installed it in the door.
Issuing and installing replacement locking components with the coding
station.
> Position a replacement locking component in factory state on the
coding station.
> Select Issue replacement cylinder in the bottom right of the