ZoneControlFeatures
TheUT‐3000comespre‐
programmedwithdefault
operatingparametersforzoned
HVACsystems.
Thedefaultprogramsettingsfree
thetechnicianfromprogramming,
andallowsfinetuningofthe
systemtooptimizeits
performance.
TheUT‐3000operatesinstaged
andmodulatingmodeatalltimes.
Minimizesblowerspeed,
ma
ximizestemperaturecontrol,
andimprovessystem
performance.
FaultFreeProgramming&IntuitiveTemperatureControl
Table1.FromEWCControlsTechnicalBulletin:TB‐241
Feature Default RangetoSelect
SystemType Heat/Cool HeatPumporHeat/Cool
HPType NONDual Fuel DualFuelorNon‐DualFuel
T‐StatType Heat/Cool HeatPumporHeat/Cool
RevValve RV‘O’ ‘O’TypeRVor‘B’TypeRV
FanMode Gas GASorHYDRO(Electric)
OASSP 15° OFFor7° to42°F
O.T.Offset 15° 5° to20°F
U.T.Offset 8° 5° to10°F
SA
S
HPTGT 100° 90° to120°F
SASGasTGT 130° 120° to170°F
SASCoolTGT 50° 42° to60°F
SASRSPDLY 30s 10s– 180s
W2Threshold 80%
65‐100%
(Adj.in5pointincrements)
PURGEFAN 25%
25‐100%
(Adj. in25pointincrements)
LegacyDMD 50% 25%,50%,75%,or100%
TotalZones 3 2or3zones
LimitSASPID N YesorNo