RS-X60-EDP / RS-X60-EDP+
Deluxe Keyless Entry & Remote Start
Installation Guide
July 7, 2014
Temporary cover. Color cover is in a separate le.
1
Question and Answer IconNeed help?

Do you have a question about the Excalibur RS-X60-EDP and is the answer not in the manual?

Excalibur RS-X60-EDP Specifications

General IconGeneral
BrandExcalibur
ModelRS-X60-EDP
CategoryRemote Starter
LanguageEnglish

Summary

Installation Considerations

6 Pin Main Wire Harness

Details regarding the connections and requirements for the 6-pin main wire harness.

RED & RED/WHITE WIRES - CONSTANT POWER (+) INPUT

Specific instructions for connecting the constant 12v power input wires.

PINK WIRE - IGNITION #1 (+) INPUT/OUTPUT

Guidance on connecting the primary ignition input/output wire for system operation.

ORANGE WIRE - ACCESSORY (+) OUTPUT

Instructions for connecting the accessory output wire for climate control and other features.

VIOLET WIRE - START (+) OUTPUT

Details on connecting the positive output wire for the vehicle's starter circuit.

PINK/WHITE WIRE - IGN#2/PROGRAMMABLE (+) OUTPUT

Information on connecting the programmable ignition #2 output wire.

14 Pin Secondary Wire Harness

BLACK WIRE - SYSTEM GROUND (-) INPUT

Instructions for connecting the system ground wire to the vehicle chassis.

ORANGE WIRE - STATUS/ANTI-GRIND (-) OUTPUT

Details on the status/anti-grind output, available on EDP+ models.

BROWN/RED WIRE - BRAKE PEDAL (+) INPUT

Guidance on connecting the brake pedal input for critical safety disengagement.

BLACK/WHITE WIRE - NEUTRAL SAFETY (-) INPUT

Instructions for connecting the neutral safety input for safe remote start operation.

VIOLET/WHITE WIRE - TACH SIGNAL INPUT

Details on connecting the tachometer signal input for engine RPM detection.

BROWN WIRE - HORN (-) OUTPUT

Information on connecting the horn output wire for audible feedback.

WHITE WIRE - FLASHING LIGHT (+) OUTPUT

Guidance for connecting the positive output for flashing parking lights.

WHITE/BLACK WIRE - FLASHING LIGHT (-) OUTPUT

Details on connecting the negative output for flashing parking lights.

GRAY WIRE - HOOD TRIGGER (-) INPUT

Instructions for connecting the hood trigger input for safety during remote start.

MANUAL TRANSMISSION CONNECTION

Details on connecting the gray wire for manual transmission door pin input.

YELLOW - ALARM IGNITION CONTROL (+) OUTPUT

Instructions for the yellow wire output controlling aftermarket alarm ignition input.

WHITE/BLUE WIRE - REMOTE START ACTIVATION (-) INPUT

Guidance on connecting the white/blue wire for activating the remote start function.

LT. GREEN/RED WIRE - OEM ALARM ARM (-) OUTPUT

Details on the green/red wire output for OEM alarm arming.

LT. GREEN/BLACK WIRE - OEM ALARM DISARM (-) OUTPUT

Information on the green/black wire output for OEM alarm disarming.

RED/WHITE WIRE - TRUNK RELEASE / CH2 (-) OUTPUT

Instructions for connecting the red/white wire for trunk release or CH2 functions.

Wiring Overview

Window-mount Antenna Module

Details on mounting and connecting the window-mount antenna module.

3 PIN DOOR LOCK PORT

Information about the 3-pin port for door lock and unlock functions.

3 PIN SAT. RELAY PORT (RED)

Details on the 3-pin satellite relay port for programmable outputs.

6 PIN POWER HARNESS

Summary of wires in the 6-pin power harness and their functions.

Green & Black Data Ports

3 Pin Satellite Relay Port (RED)

GREEN WIRE - START (-) PROGRAMMABLE OUTPUT

Instructions for the green wire's programmable negative start output.

RED WIRE - CONSTANT (+) OUTPUT

Details on the red wire's constant positive output for relay coils.

BLUE WIRE - IGNITION (-) OUTPUT

Information on the blue wire's programmable negative ignition output.

3 Pin Door Lock/Unlock Port (RED)

GREEN WIRE - LOCK (-) OUTPUT

Instructions for the green wire's negative pulse output for locking.

CENTER PIN (EMPTY) - CONSTANT (+) OUTPUT

Description of the center pin's constant positive output for interfaces.

BLUE WIRE - UNLOCK (-) OUTPUT

Details on the blue wire's negative pulse output for unlocking.

Status Lights

Valet / Programming Switch

Window Mount Antenna Module

Details on mounting and connecting the window-mount antenna module.

Tach Programming

Programming Transmitters

Programming Features

User Feature Programming

Remote Start Run Time

Configuration for the duration of the remote start sequence.

Flashing Light Confirmations

Setting options for visual confirmations via flashing lights.

Confirmation Chirp Volume

Adjusting the volume level for audible system confirmations.

BROWN WIRE: Siren/Horn

Configuration options for the brown wire's siren or horn output.

Ignition Lock / Unlock

Setting ignition lock and unlock behavior for remote start.

Door Open Bypasses

Options for bypassing door status detection during operation.

Unlock w/ Trunk Release

Enabling unlock function in conjunction with trunk release.

RS Activation (Remote)

Defining remote start activation methods via transmitter buttons.

Last Door Arming

Configuration for arming the system after the last door is closed.

Automatic Rearming

Settings for automatic re-arming of the security system.

Confirmation Chirps

Customizing audible confirmation chirps for system events.

Anti-Carjacking

Configuring the anti-carjacking feature for security.

Installer Feature Programming

RS Activation (WHITE/BLUE wire)

Programming the remote start activation input pulse count.

PINK/WHITE Wire

Configuring the function of the pink/white wire.

Engine Detection

Selecting the method for engine detection (Tachless, Tach Wire).

Gasoline or Diesel Engine

Specifying engine type for optimal remote start operation.

Sat Port GREEN Wire

Programming the green wire output on the satellite relay port.

Sat Port BLUE Wire

Programming the blue wire output on the satellite relay port.

Crank Time

Setting the duration for engine cranking during remote start.

Door Lock Output

Configuring the pulse duration for door lock/unlock outputs.

Remote Start Lock Control

Defining lock behavior relative to remote start activation.

Turbo Timer

Setting the duration for the turbo timer function.

Manual Transmission

Enabling and configuring settings for manual transmission vehicles.

Data Port Protocol

Selecting the communication protocol for data ports.

Virtual Alarm

Enabling or disabling the virtual alarm feature.

Pulse Ign. on Disarm

Configuring ignition pulse behavior upon disarming the system.

Lock On Prewarn

Setting the system to lock upon pre-warning activation.

Starter Interrupt (EDP+ Models ONLY)

Configuring starter interrupt for EDP+ models.

Low Temp Crank Ext. (EDP+ Models ONLY)

Extending crank time for low-temperature starts on EDP+ models.