XP600/1100/2000 INSTALLATION AND OPERATION MANUAL
Inverter requires adequate ventilation for cooling. With proper
cooling, the inverter will operate efficiently and meet its published
ratings. All models can be mounted in several positions. Best
position, with fan down. Second best, horizontal. Third, vertical
with fan up. Least preferred, upside down.
Inverter should be mounted as close to the battery as possible.
Shorter wire has less resistance, which translates to increased
efficiencies.
An in line fuse is recommended, to protect the battery and wiring to
the inverter. This fuse should be located very close to the battery
positive (+) terminal. To select appropriate size fuse, consult the
"Rated and Peak Current" table in appendix "A".
Disconnect the
charger and inverter are off.
Make DC input connections to the inverter as illustrated in
“Appendix C”.
(Optional) Using 12-18 AWG wire, make Remote On/Off
connection from the rear panel terminal labeled “REMOTE” to
one pole of a small toggle switch. Then from the other pole of
toggle switch, make a connection to battery negative (-). Make
sure the toggle switch is in the off position.
Reconnect grounded terminal of the battery.
2.
3.
INSTALLATION (Wiring)
1.
2.
3.
4.
.
.
.
.
.
.
.
.
grounded terminal of battery and make sure the
Page 10