9 System Settings
Activation of Systems Settings in System Mode:
Normal operation If JMobile runtime is not running: Press “System Setting” button on the HMI
screen to enter in System Settings in User Mode. Select “Restart” -> “Cong
OS” to reboot in System Mode.
If JMobile runtime is running: recall context menu and select “System
Settings”. To recall the context menu click and hold any unused area of the
touchscreen for a few seconds. Default hold time is 2 seconds to enter in
System Settings in User Mode. Select “Restart” -> “Cong OS” to reboot in
System Mode.
Recovery operation If panel is not responsive, use the so-called “tap-tap” procedure. This
procedure consists in tapping the surface of the touchscreen during the
device power-up phase. Tapping frequency must be high. You have to start
tapping the touchscreen as soon as power has been applied to the device.
When the sequence has been recognized, the system shows the message:
“TAP-TAP DETECTED”. At this point release touch to boot in
User Mode without running JMobile runtime or press and hold few seconds
(selecting so “RESTART: CONFIG OS”) to boot in System Mode.
System Settings includes options for basic settings of the device.
Language Congure language used for System Setting menu only.
System show informations about platform, status and timers (like System on time, backlight on
time).
Logs enable persistent log for BSP and allows to export it.
Date & Time change the device date and time, including time zone and NTP Server
Network congure IP Address of Ethernet interface and the other network settings like DNS,
Gateway, DHCP, Hostname.
Services Enable/disable services. Example of services are OpenSSH server, Cloud services,
SNMP and logging.
Management update of BSP components (Main OS, Cong OS, Boot loader, XLoader), check for
partitions consistence, update of splash screen, informations about usage and size of
partitions.
The update of Main OS is available only in System Mode, the update of Cong OS is
only in User Mode.
Display adjust brightness, congure automatic backlight turnoff and select HMI orientation
(90°, 180°, 270° and 360°).
Restart restart the device. “Main OS” option restarts as per default in User Mode, “Cong OS”
option restart panel directly into System Settings in System Mode
Authentication congure password for administrator (“admin”) and for the standard user (“user”).
Administrator has full access to System Settings (updates of BSP and other system
components). Standard user has some limitations.
Note: The System Settings tool includes also other options, not described and not documented at this moment.