In this mode, the KT-9 is operated as a conventional
unit, requiring you to manually zero the unit and take the read-
ing as done with the older KT-5. Please refer toN
O
-P
IN
mode
on page 24 for a detailed description on the use of this mode.
C
ORE
In this mode, you can take measurements of selected
core diameters and have the KT-9 automatically apply geomet-
ric correction calculations to give a true reading. Please refer to
“C
ORE
mode” on page 27 for a detailed description on the use
of this mode.
S
CAN
In this special sub-mode of the
N
O
-P
IN
or
C
ORE
modes,
the KT-9 continuously samples at a rate of 3 times per second.
The unit also emits an audio tone that is directly proportional to
the measured susceptibility. This mode may also be used for
core logging with optional digital recording, as required. Please
refer to “S
CAN
mode” on page 31 for a detailed description on
the use of this mode.
To select operating mode
To select the mode you wish to take measurements in, you will
need to activate the A: (
ACCESS
) menu and toggle between the
three modes. The
ACCESS
menu is only available when the data
memory is empty, so you may have to clear your stored read-
ings. Please also refer to Figure 4 on page 14, which schemati-
cally shows the KT-9 configuration sequence.
1
Press the
R
IGHT
button.
2
Make sure that there is no data in memory. If the display
shows C: 0, then the memory is empty. Otherwise you will
have to clear the memory as described on page 37.
3
Wait 10 seconds and the system will return to:
r: nP
17
N
O
-P
IN
In this mode, the KT-9 is operated as a conventional
unit, requiring you to manually zero the unit and take the read-
ing as done with the older KT-5. Please refer to “N
O
-P
IN
mode”
on page 24 for a detailed description on the use of this mode.
C
ORE
In this mode, you can take measurements of selected
core diameters and have the KT-9 automatically apply geomet-
ric correction calculations to give a true reading. Please refer to
“C
ORE
mode” on page 27 for a detailed description on the use
of this mode.
S
CAN
In this special sub-mode of the
N
O
-P
IN
or
C
ORE
modes,
the KT-9 continuously samples at a rate of 3 times per second.
The unit also emits an audio tone that is directly proportional to
the measured susceptibility. This mode may also be used for
core logging with optional digital recording, as required. Please
refer to “S
CAN
mode” on page 31 for a detailed description on
the use of this mode.
To select operating mode
To select the mode you wish to take measurements in, you will
need to activate the A: (
ACCESS
) menu and toggle between the
three modes. The
ACCESS
menu is only available when the data
memory is empty, so you may have to clear your stored read-
ings. Please also refer to Figure 4 on page 14, which schemati-
cally shows the KT-9 configuration sequence.
1
Press the
R
IGHT
button.
2
Make sure that there is no data in memory. If the display
shows C: 0, then the memory is empty. Otherwise you will
have to clear the memory as described on page 37.
3
Wait 10 seconds and the system will return to:
r: nP