EasyManuals Logo

Extech Instruments CTH10A User Manual

Extech Instruments CTH10A
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
EXTECHINSTRUMENTS
3CTH10AenGB_V2.310/15
Operation
GettingStarted
Open the rear battery compartment, insert three (3) ‘C’ type batteries observing correct
polarityandthencloseandsecurethecompartmentcover.PresstheResetbutton(usingthe
tipofapapercliporpin)inordertoinitializethemeter.
AutomaticTimeSetting
Afterinsertingthebatteriesandresettingtheunitasdescribedabove,theclock
automaticallyscansfortheWWVBtimesignalandtheicon
flashesontheLCD.
flashes
Indicatingnowisreceiving
WWVBsignal
turnson
Indicatingsignalreceived
successfully
disappears,
Indicatingsignal
receptionfailed
TheclockautomaticallysynchronizeswiththeWWVBradiosignaleverydayat2amto
maintainaccuratetime. Ifsynchronizationwiththesignalfails,thesignalicondisappears;
theclockthenattemptstosynchronizewiththeWWVBsignalat3,4,and5am.
Theclockcanbesettoscan
thetimesignalmanuallybyholdingthe button(B4)for3
seconds.Note:Ifamanualscanisattemptedwiththesignaliconshowing,thesignaliconwill
disappearandthemanualscanwillhavetobeattemptedagain.Eachreceptiontakesabout
5minutes.Ifreceptionfails,scanningstopsandthesignalicondisappears;thescan
then
repeatsonthenextfull hour(e.g.ifascanfailedat8:20amascanwillbetriedagainat9am).
Stopscanningbyholding
button(B4)for3seconds.
Note:ButtonswillnotfunctionwhilescanningfortheWWVBtimesignal.
ManualTimeSetting
Inthetimedisplaymode,holdthe“MODE”button(B2)for3secondstoenterthe
Clock/CalendarsettingMode.
Press“+”(B3)or (B4)buttontoadjustthesettingandpressthe“MODE”button(B2)to
confirmeachsettingandmovetothenextsetting.
The
settingsequenceisasfollows:Hour,Minute,Second,Year,Month/Daysequence,
Month,Day,DST.
Notes:
1. Allsettingmodeswillautomaticallyexitafter15secondsofinactivity.
2. Pressandholdtheplusorminusbuttonforfasterscrollingofdigitswhileediting.
3. ForTimeZones:Thedefaultsetting
iszone“P”.Hold“+”(B2)buttonfor3secondstochange
toanotherzone“P”“M”“C”or“E”Pacific,Mountain,Central,andEastern.
4. DST:WhentheDSTfunctionisactivated(DaylightSavingMode)“DST”willbeshownonthe
LCD.Set‘DST’asdescribedintheManual
TimeSettingsectionabove.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments CTH10A and is the answer not in the manual?

Extech Instruments CTH10A Specifications

Temperature Measurement IconTemperature Measurement
temperature measurement range0~50°C (32~122°F)
storage temperature‐20~60°C (‐4~140°F)
temperature resolution0.1°C or °F
temperature accuracy ‐5°C to 0°C±1.5°C (±3°F)
temperature accuracy 1°C to 30°C±1°C (±2°F)
temperature accuracy 31°C to 50°C±3°F (±1.5°C)
Humidity Measurement IconHumidity Measurement
r.h. measurement range20~99% Relative Humidity
r.h. accuracy 20% to 40% RH±8% RH (@25°C)
r.h. accuracy 41% to 70% RH±6% RH (@25°C)
r.h. accuracy 71% to 90% RH±8% RH (@25°C)
Power IconPower
power supplyThree (3) ‘C’ type batteries
Weight and Dimensions IconWeight and Dimensions
dimensions29 x 43 x 3.8 cm (11.4 x 17 x 1.5 in.)
weight1.25 kg (2.75 lbs.)