12
2 - Eddystone URL
3 - Eddystone TLM
4 - iBeacon
5 - Omni ID Custom Advert
(Default)
0004
Local Name String, Max
Length 10 Chars
Default = “SenseBLE”
Only Ascii Characters 0x20
to 0x7E accepted
R/W
String 10
0006
Eddystone UID
R/W
uint8_t [16]
0007
Eddystone UID Reserved
Value
R/W
uint8_t [2]
0008
Eddystone URL, this is
encoded,
First byte (Review the table
above)
Following bytes can
optionally use the short
codes for domains
Default = "https://omni-
id.com/ble/"
R/W
uint8_t [17]
000A
Motion Alarm Sensitivity
0 - Disabled
1 - Least sensitive
10 - Most sensitive
R/W
000B
Activity Threshold Seconds
R/W
000C
Activity Window Seconds
R/W
000D
Stationary → Moving
Threshold in seconds
R/W
000E
Moving → Stationary
Threshold in seconds
R/W
0010
iBeacon UID
R/W
uint8_t [16]
0011
iBeacon Major
R/W
uint8_t [2]
0012
iBeacon Minor
R/W
uint8_t [2]
0020
Idle beacon advertisement
frequency in milliseconds
100ms to 1 Second, 10ms
resolution
1 Second onwards, 1
Second resolution
Max of 3,600,000 (1 Hour)
R/W
uint32_t
Little Endian
0021
Moved beacon
advertisement Frequency.
in milliseconds
100ms to 1 Second, 10ms
resolution
1 Second onwards, 1
Second resolution
R/W
uint16_t
Little Endian
0022
Button pressed
advertisement frequency in
milliseconds
100ms to 5 Second
R/W
uint16_t
Little Endian
0023
Moved State Seconds
1 Second to 60 Seconds
Period that the state is
active after movement
stops and the movement
state machine moves to
stationary
R/W
uint16_t
Little Endian