EYELA Cool Ace - User Manual

EYELA Cool Ace
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Tokyo Rikakikai Co., Ltd.
CA-1116A 220V
R00
Instruction
Manual
This instruction manual is designed to use the product safely with keeping
its best performance.
Please keep this manual in a place easily accessible to every users.
IMPORTANT
Be sure to read “Safety precautions” before use.
Low Temperature Circulator
Cool Ace

Questions and Answers

  • N
    Nicole JohnsonAug 13, 2025
    What to do if the EYELA Cool Ace Laboratory Equipment residual current device cannot be turned on?
    • J
      joseph99Aug 13, 2025
      If the residual current device cannot be turned on, it could be due to an electric leakage hazard or excess current flow. In the event of an electric leakage hazard, immediately stop operation and contact your local dealer or closest customer service center.
  • P
    powelljohnAug 17, 2025
    What to do if the EYELA Laboratory Equipment refrigeration unit does not work?
    • D
      Donald HuffAug 17, 2025
      If the refrigeration unit isn't working, it could be due to several reasons: the high-pressure switch for the refrigeration unit or overload relay protection circuit might be activated, the refrigeration unit might be impaired, or the water level may be low, exposing the cooling coil. If the thermal load is extremely large, reduce the load. If the refrigeration unit is impaired, stop operation and contact your local dealer or closest customer service center. If the water level is low, fill the circulation liquid in the low-temperature circulation bath.
  • M
    Michael ToddAug 25, 2025
    Why is there no display shown on the indicator when turning on the power switch of EYELA Cool Ace Laboratory Equipment?
    • C
      Carol LuceroAug 25, 2025
      If no display is shown when turning on the power switch, it could be due to several reasons: the mains connector may not be plugged into the outlet completely, power may not be supplied, the residual current device may be turned off or impaired, or the power switch or temperature controller may be impaired. Plug the main connector in after turning off the residual current device and power switch. Turn on the breaker of the distribution board. Turn on the residual current device. If the residual current device is impaired, stop operation and contact your local dealer or closest customer service center.
  • E
    ebrownAug 28, 2025
    Why is my EYELA Cool Ace Laboratory Equipment bath frozen at -7°C or higher?
    • A
      Amy CrawfordAug 28, 2025
      If the bath internals are frozen, it could be due to poor circulation because of pressure loss of piping, or the temperature controller is broken, or the refrigeration unit cannot be stopped. Open the valve for adjusting discharge volume. Use antifreeze. Using a high-pressure pump is recommended. If the temperature controller is broken or the refrigeration unit cannot be stopped, stop operation and contact your local dealer or closest customer service center.
  • C
    Crystal BryantSep 1, 2025
    What to do if cool water does not circulate in my EYELA Cool Ace Laboratory Equipment?
    • R
      Robert MartinezSep 1, 2025
      If cool water isn't circulating, it could be that the valve for adjusting discharge volume is closed, dirt adheres to the strainer of the low-temperature circulation bath, or air is being sucked in. Open the valve for adjusting discharge volume. Remove the dirt from the strainer. Remove the drain stopcock and make sure that cool liquid flows, then attach the stopcock again. Turn the pump switch on and off two or three times to release the air.
  • S
    smithericaSep 4, 2025
    What to do if the circulation volume is small in EYELA Laboratory Equipment?
    • S
      Scott PerezSep 4, 2025
      If the circulation volume is small, it could be because the circulation nozzle has a smaller diameter, the hose is crushed, or the pressure loss of the circulation system is too much. Replace the nozzle with the supplied nozzle that has a larger diameter. Stretch the hose. Reduce the pressure loss.
  • R
    Ryan AverySep 8, 2025
    Why temperature cannot be controlled and there is abnormal indication in EYELA Cool Ace Laboratory Equipment?
    • A
      Alyssa NelsonSep 8, 2025
      If the temperature cannot be controlled and there is an abnormal indication, it is because the temperature controller is in an abnormal state due to noise. Change the installation site. Set the room temperature at 35°C or lower. If that failure mode still remains, stop operation and contact your local dealer or closest customer service center.
  • J
    Joel NelsonNov 19, 2025
    What to do if the EYELA Cool Ace Laboratory Equipment alarm is activated?
    • M
      matthew63Nov 19, 2025
      If the alarm is activated on your EYELA Laboratory Equipment, it could be due to several reasons: the high-pressure switch or overload relay holding circuit for the refrigeration unit may be activated, there may be a disconnection of the temperature sensor, an upper or lower temperature limit alarm may have been triggered, or a power failure recovery alarm may have been issued. Set the ambient temperature at 35°C or lower. If the heat load is out of cooling capability, reduce the load. Check the fan for the refrigeration unit. Check the power and voltage, ensuring the rating voltage is 220V±10%. For a disconnected temperature sensor, stop operation and contact your local dealer or closest customer service center. For upper temperature limit alarm, after confirming that the bath temperature...

Summary

IMPORTANT SAFETY INFORMATION

1. Warning signal word

Defines warning symbols and their meanings for safe operation.

2. Warning Display on the Product

Shows the location and meaning of warning labels on the product.

Details of items in the package

Package Contents List

Provides a comprehensive list of all included items with quantities and part identifiers.

1 For safe operation of the unit

General Safety Precautions

Consolidates critical safety warnings and advice for daily use.

2 Product overview

2-1 Applications

Describes the intended uses and applications of the low temperature circulator.

2-2 Specification

Details the technical specifications, performance, and components of the unit.

2-3 Cooling capability curve (Reference)

Presents a graphical representation of the unit's cooling performance under different conditions.

2-4 Circulation capability (Reference)

Shows graphs illustrating the unit's circulation performance related to flow volume and lifting height.

2-5 Names of parts

Identifies and labels all external and internal parts of the unit for user reference.

3 Names and functions of operating portion

3-1 Control panel

Details the components of the control panel and their respective functions.

3-2 Safety alarm features

Lists the safety devices and alarm functions integrated into the unit.

4 Installation

4-1 Installation environment

Specifies the recommended environmental conditions for installing the unit safely and effectively.

4-2 Installation conditions

Outlines the necessary spatial clearances and conditions around the unit for optimal operation.

4-3 Installation

Details the step-by-step process for physically installing the unit, including caster handling.

4-4 Utility connection

Explains how to safely connect the unit to the power source and grounding.

5 Operation

5-1 Preparation

Describes the necessary steps and precautions before operating the unit, including piping and hose connections.

5-2 How to operate the unit

Provides instructions on setting temperature and starting the circulation pump and control.

3. Stopping operation

Details the correct procedure for stopping the unit and its circulation pump.

4. After operation

Explains the steps to take after completing the operation, including draining the unit.

5-3 Operation in the user setting mode

Guides users on how to access and adjust user-specific settings and parameters.

5-4 Optional Accessories

5-4-1 Circulation to open system

Explains how to set up the unit for circulation to an open system using accessories.

5-4-2 Other options

Describes additional optional accessories for specific applications, like metallic nozzles.

8 Consumption parts;Optional accessories

Parts and Accessory Listing

Provides a detailed catalog of consumable parts and optional accessories with identification codes.

9 Disposal of the product

Product Disposal Instructions

Outlines the procedures for safely disposing of the main unit and its components.

7 Maintenance checkup

7-1 Operation test for residual current device

Describes how to perform a functional test on the residual current device for safety.

7-2 Cleaning and caring the product

Provides guidelines for cleaning and maintaining the unit to ensure its longevity and performance.

10 After-sale Services

Support and Repair Information

Provides contact information and procedures for obtaining product support and repair services.

EYELA Cool Ace Specifications

General IconGeneral
BrandEYELA
ModelCool Ace
CategoryLaboratory Equipment
LanguageEnglish