    Veronica PowellSep 10, 2025
    Why is the temperature not stable in my EYELA Accessories?
    • T
      Teresa ReyesSep 10, 2025
      Temperature instability in your EYELA Accessories can be caused by constant changes in room temperature due to the influence of an air conditioner. Ensure the unit is placed where the air conditioner's airflow does not directly affect it.
  • B
    Brian HillAug 22, 2025
    What should I do if the EYELA LTI-1200E refrigeration unit does not work properly?
    • M
      murphyrobertAug 22, 2025
      If the refrigeration unit of your EYELA Accessories does not work properly, reduce the load. For the settings for under cooling protector, set the temperature -10° lower than setting temperature of temperature controller. In case the setting temperature is too high, set the value up to 40°.
  • C
    Chad HoffmanAug 25, 2025
    What to do if no display is shown on the indicator of EYELA Accessories when turning on power switch?
    • N
      Nathan PenningtonAug 25, 2025
      If there's no display when you turn on the power switch of your EYELA Accessories, first, turn off the residual current device and power switch, then ensure the power plug is securely connected to the outlet. Also, check if the breaker of distribution board is on. Ensure the residual current device is turned on. If the residual current device is impaired, immediately stop running the product and contact your local agency or the closest customer service center.
  • K
    Kristen MorganAug 26, 2025
    What should I do if the temperature of my EYELA Accessories does not rise up to the setting value?
    • T
      thompsonchristopherAug 27, 2025
      If the temperature of your EYELA Accessories unit does not rise to the set value, reduce the number of sample and vessel. For the settings for under cooling protector, set the temperature 10° higher than setting temperature of temperature controller. In case the setting temperature is too low, set the value higher than 30°. If the ambient temperature is too low, set the temperature higher than 5°.
  • J
    Jasmine ParkerAug 27, 2025
    Why can't my EYELA Accessories unit be temperature controlled?
    • G
      Glenn McphersonAug 27, 2025
      If your EYELA Accessories unit cannot be temperature controlled, it may be because the heater is disconnected or the refrigeration unit is impaired. If the heater is disconnected, immediately stop running the product and contact your local agency or the closest customer service center.
  • B
    Brian LawrenceAug 29, 2025
    What causes the upper temperature limit alarm to activate on my EYELA LTI-1200E?
    • D
      David SimmonsAug 29, 2025
      The upper temperature limit alarm on your EYELA Accessories can activate if too many samples and vessels in the chamber prevents the convection flow of the heat. Reduce the number of sample or vessel to resolve this.
  • H
    Heather MillerSep 18, 2025
    Why is there a difference between the displayed and actual temperature on my EYELA LTI-1200E?
    • B
      Brian PhillipsSep 18, 2025
      The difference between displayed and actual temperature on your EYELA Accessories is because of the different accuracy of the temperature controller and sensor. Set the setting for calibrating displayed temperature.
  • J
    Jason BrennanSep 12, 2025
    What should I do if the door alarm, temperature control failure alarm, or temperature not rising alarm is activated on my EYELA Accessories?
    • H
      Holly BellSep 12, 2025
      If the door alarm, temperature control failure alarm, or temperature not rising alarm is activated on your EYELA Accessories, it's likely that the door is not closed completely. Ensure the door is fully closed.
  • N
    ngloverSep 8, 2025
    What causes the lower temperature limit alarm to activate on my EYELA Accessories?
    • L
      laura94Sep 8, 2025
      The lower temperature limit alarm on your EYELA Accessories can activate if too many samples and vessels in the chamber prevents the convection flow of the heat, or if the heater is disconnected. Reduce the number of sample or vessel. If the heater is disconnected, immediately stop running the product and contact your local agency or the closest customer service center.
  • B
    Brooke JonesSep 5, 2025
    Why is there dew condensation on the wall of the EYELA LTI-1200E chamber?
    • H
      Hannah FlynnSep 5, 2025
      Dew condensation on the wall of the EYELA Accessories chamber can occur depending on the settings, ambient temperature, or humidity in the chamber. Wipe the dew off with a soft cloth.

Summary

Safety Precautions

Signal Word Definitions

Explains the meaning of alert marks and signal words used in the manual.

Safety Use Guidelines

Safety Use Considerations

Emphasizes caution due to the lack of explosion-proof structure.

Product Warning Labels

Product Specifications

Control Panel Overview

Control Panel Layout and Functions

Explains the layout and function of the control panel buttons and indicators.

Operation Modes

Adjustment Mode Settings

Safety and Alarm Functions

Installation

Installation Environment Requirements

Specifies suitable conditions for installing the unit to ensure optimal performance.

Installation Conditions and Handling

Provides installation conditions and cautions for carrying the unit.

Installation Procedures

Utility Connections

Operation Preparation

Sample Placement in Chamber

Operating the Unit

Constant Number Operation

Timer Mode Operations

Auto Stop Operation

Auto Start Operation

Step Operation

24-Hour Cycle Operation

Operating Adjustment Modes

Upper Temperature Limit Alarm

Lower Temperature Limit Alarm

Power Recovery Settings

Manual Defrosting (Forced Defrosting)

Troubleshooting

Maintenance and Checking

Component Replacement

Changing Door Opening Side

After-Sales Support

EYELA LTI-1200E Specifications

General IconGeneral
BrandEYELA
ModelLTI-1200E
CategoryAccessories
LanguageEnglish

Related product manuals