ENGLISH
5
3.3 ELECTRIC CONNECTIONS3.3 ELECTRICAL CONNECTIONS
a
220 V ~
220 V ~
a
b
YELLOW-GREEN
BLUE
BROWN PHASE
NEUTRALWIRE
PUSH-BUTTON
AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL
ONLY:Forthistypeofconfiguration,connecttheblueand
browncablesofthemotortothemainspowersupplyand
theyellow-greencabletoearth.Do not connect the RED
(or black) wire.
Do not cut the red (or black) cable if it is not
used, just insulate it
AUTOMATED SYSTEM CONTROLLED BOTH BY REMOTE
CONTROL AND BY PUSH-BUTTON: For this type of
configuration,connectthemotorasshownintheprevious
diagram,fig.6.
The push-button has a step-by-step logic:
each pressure exerted on the push-button
sends a pulse to the motor (I.E.: FIRST PULSE UP
- SECOND PULSE STOP - THIRD PULSE DOWN etc.).
After a down or up command, the motor stays
active until the relevant travel limit has been
reached.
TheseriesRtubularmotorcanbecontrolledbothbythe
remote control and by a push-button with step-by-step
logic.
TheseriesWtubularmotorcanbecontrolledbothbythe
remote control and by a push-button with step-by-step
logic. In addition,a wind sensor (anemometer) canbe
connectedtothemotor:itcommandstheclosure of the
rolling shutter assoonasthewindhasreachedaspeed
higherthan20Km/h.
WHEN THE ANEMOMETER OPERATES, THE MOTOR
DIRECTION OF ROTATION CORRESPONDS TO THAT
CONTROLLED BY THE UP PUSH-BUTTON OF THE
REMOTE CONTROL. THE DOWN COMMAND IS
INHIBITED FOR 16 min.
AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL
AND ANEMOMETER:Forthistypeofconfiguration,connect
theblueandthe brownwire ofthe motortothemains
power,andtheyellow-greenwiretoearth.Donotconnect
thered(orblack)wire.
THEANEMOMETERmustbeconnectedasshowninfigure7.
AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL,
PUSH-BUTTON AND ANEMOMETER: For this type of
configuration,connectthemotorasshowninthediagram
offigure7.
Fig.6
Fig.7
YELLOW-GREEN
BLUE
BROWN
RED
(ORBLACK)
PUSH-BUTTON
WHITE
ANEMOMETER
The push-button has a step-by-step logic:
each pressure exerted on the push-button
sends a pulse to the motor (I.E.: FIRST PULSE UP
- SECOND PULSE STOP - THIRD PULSE DOWN -etc.).
After a down or up command, the motor stays
active until the relevant travel limit has been
reached.
Do not cut the red (or black) cable if it is not
used
.
RED
ORBLACK
PHASE
NEUTRALWIRE