EasyManua.ls Logo

Faber AXIA User Manual

Faber AXIA
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AXIA
Wall Mount Canopy Rangehood
• Installation Instructions
• Use and Care Information
READ AND SAVE THESE INSTRUCTIONS
The Installer must leave these instructions with the homeowner. The
homeowner must keep these instructions for future reference and for
local electrical inspector's use.
LISEZ BIEN CETTE FICHE AVANT D'INSTALLER LA HOTTE
AVERTISSEMENT - POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA TABLE DE CUISSON : Ne jamais laisser
un élément de la table de cuisson fonctionner sans sur-veillance à la puissance de chauffage maximale; un renversement/
déborde-ment de matière graisseuse pourrait provoquer une inflammation et le génération de fumée. Utiliser toujours une
puissance de chauffage moyenne ou basse pour le chauffage d’huile. Veiller à toujours faire fonctionner le ventilateur de
la hotte lors d’une cuis-son avec une puissance de chauffage élevée ou lors de la cuisson d’un mets à flamber. Nettoyer
fréquemment les ventila-teurs d’extraction. Veiller à ne pas laisser de la graisse s’accumuler sur les surfaces du ventilateur
ou des fil-tres. Utiliser toujours un ustensile de taille appropriée. Utiliser toujours un usten-sile de taille adapté à la taille de
l’élé-ment chauffant.
AVERTISSEMENT: - POUR PRÉVENIR LES BLESSURES EN CAS DE FEU SUIVRE LES RECOMMANDATIONS SUIVANTES:
ÉTOUFFEZ LE FEU avec un couvercle métallique et fermez le brûleur. Si le feu ne s'éteint pas tout de suite, QUITTEZ LES
LIEUX ET APPELEZ LES POMPIERS. NE TOUCHEZ JAMAIS UNE CASSEROLE EN FLAMMES. N'UTILISEZ JAMAIS DE L'EAU
ou un torchon mouillé pour éteindre le feu - ce qui pourrait causer une explosion de vapeur. N'utilisez un extincteur que
si: 1. Vous avez un modèle ABC et vous connaissez bien son mode d'emploi. 2. Le feu est petit et peu répandu. 3. Les
pompiers sont déjà prévenus. 4. Vous avez une sortie derrière vous.
TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER À PROXIMITÉ DE LA HOTTE DOIT ÊTRE SCELLÉ
Gardez 24 po. de hauteur entre le bas de la hotte et la surface de cuisson. Cette hauteur minimum peut être plus haute suivant le
code municipal. Par exemple, les cuisinières à gaz peuvent requérir 30 po. de hauteur. Les armoires au-dessus de chaque côté
devront être au moins à 18 po. au-dessus de la surface de cuisson. Consultez la fiche technique avant de découper les armoires.
L'installation de cette hotte doit être conforme aux Réglements de Manufactured Home Construction and Safety Standards, titre 24
CFR, Section 3280 (anciennement Federal Standard for Mobile Home Construction and Safety Standards, titre 24 CFR, Section 3280
(anciennement Federal Standard for Mobile Home Construction and Safety, titre 24, HUD, Section 280). Le branchement électrique
se fait avec une raccordement à 4 fils. Consultez la fiche technique électrique.
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn
hood ON when cooking at high heat or when cooking flaming foods. Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING: SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CARE-
FUL TO PREVENT BURNS. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER
PICK UP A FLAMING PAN - You may be burned. DO NOT USE WATER, including wet dishcloths or towels - a violent steam
explosion will result. Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you already know
how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. 4.
You can fight the fire with your back to an exit.
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop. This
minimum clearance may be higher depending on local building code. For example, for gas ranges, a minimum of 30" may be required.
The maximum depth of overhead cabinets is 13". Overhead cabinets on both sides of this unit must be a minimum of 18" above the
cooking surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer before making any
cutouts. MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured Home Construction
and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD,
Part 280). Four wire power supply must be used and the appliance wiring must be revised. See Electrical Requirements.
Version 02/02 - Page 1
Question and Answer IconNeed help?

Do you have a question about the Faber AXIA and is the answer not in the manual?

Faber AXIA Specifications

General IconGeneral
BrandFaber
ModelAXIA
CategoryVentilation Hood
LanguageEnglish

Summary

General Safety and Installation Overview

Save Instructions and Initial Warnings

Emphasizes saving instructions and provides initial safety warnings for users.

Grease Fire Prevention and Response

Details critical steps to prevent and respond to range top grease fires.

Installation Clearance and Mobile Home Rules

Specifies required clearances, sealing, and mobile home installation standards.

Venting and Electrical Setup

Venting Requirements and Ductwork Guidance

Outlines ductwork requirements, material recommendations, and termination rules.

Electrical Supply and Wiring

Details power supply, wiring standards, grounding, and connection requirements.

Electrical Safety Precautions

Highlights critical electrical safety measures, including qualified installation and service.

Installation Planning and Measurements

Tools, Parts, and Installation Plan

Lists necessary tools and parts, and advises on planning the installation method.

Dimensions and Ductrun Calculation

Provides installation dimensions and guidance for calculating ductrun length.

Handling and Installation Safety Warning

Warns about the weight and size, requiring multiple people for safe installation.

Wall Preparation and Canopy Mounting

Preparing the Installation Wall

Details steps for preparing the wall, including marking and installing mounting screws.

Canopy Assembly and Attachment

Guides on assembling the canopy, attaching components, and securing it to the wall.

Chimney Installation and Electrical Connection

Installing the Chimney Sections

Provides instructions for assembling and attaching the chimney sections to the canopy.

Wiring and Final Testing

Explains how to connect internal wiring, power supply, and perform initial operational tests.

Product Care and Maintenance

Warranty Service and Contact Information

Details the limited warranty and how to obtain service or identify distributors.

Control Panel Operation and Usage Tips

Explains the function of each control button and offers tips for optimal performance.

Cleaning Filters and Replacing Lamps

Provides instructions for cleaning the grease filters and replacing the light lamps.