30
DC Voltage
Input impedance: 10MΩ.
Maximum input voltage: 600V DC or AC (RMS).
AC Voltage
Input impedance: 10MΩ.
Maximum input voltage: 600V DC or AC (RMS).
Frequency response: 45Hz~65Hz.
Resistance
Overload protection: 250V DC or AC (RMS).
Measuring
range
Resolution Accuracy
6V 0.01V
±(0.5% of reading + 3 digits)
60V 0.1V
600V 1V
Measuring
range
Resolution Accuracy
6V 0.01V
±(0.8% of reading + 5 digits)
60V 0.1V
600V 1V
Measuring
range
Resolution Accuracy
2KΩ 0.001KΩ
±(0.8% of reading + 3 digits)
20KΩ 0.01KΩ
200KΩ 0.01KΩ
2MΩ 0.001MΩ
10MΩ 0.01MΩ ±(1.0% of reading + 5 digits)
NU-711B_0618 7 langues.indd 30 22/06/2018 09:20:54