IMPORTANT: all of the electrical connections and wiring (Pic. 21) must be completed in compliance with installation standards and in
accordance with current laws in force (Machinery Directive 2006/42/CE); they must be carried out by qualified, technical personnel,
formulating a complete analysis of all risks and adopting appropriate safety measures in accordance with the regulations EN 12445 and
EN 12453 when filling out the Technical File.
- The Elpro 13 exp programmer should be installed in a dry, protected place, inside its own container; in the case of added components,
for the proper operation of the control and safety accessories, it is advised to install everything inside a cabinet certified for outdoor
use (not provided by the manufacturer).
- The Elpro 13 exp programmer is powered by 1 mm
2
diameter electrical cables, for a maximum distance of up to 50 meters. For distances
longer than 50 meters, use electrical cables with wires of appropriate diameter, in accordance with good installation technique. For
all the accessories outside the electrical panel, electrical cables with 1 mm
2
or 0.5 mm
2
diameter wires can be used.
Key:
1 - Miri 4 Flashing lamp (code 4600)
2 - Elpro 13 exp control box (code 7079)
3 - Mains switch 230V - 50Hz Magnetic-thermal differential 0.03A
(not provided by the manufacturer) (for distances longer than 100m,
use 2.5 mm
2
section cable)
4 - Junction box (not provided by the manufacturer)
5 - Left Combi 740
6 - Trifo 11 Projector Photocell (internal) on post (code 108)
7 - Left leaf open gate stop (not provided by the manufacturer)
8 - Jubi 433 Transmitter (code 4334)
9 - Electric lock with closing leaf stop (code 7083)
10 - Right leaf open gate stop (not provided by the manufacturer)
11 - Trifo 11 Receiver photocell (internal) on post (code 108)
12 - Right Combi 740
13 - Chis 37 Key-switch (code 371)
14 - Jubi 433 radio receiver, stand alone (code 4330)
15 - Birio A8 Aerial (code 4605)
16 - Trifo 11 Projector photocell (external) (code 107)
17 - Trifo 11 Receiver photocell (external) (code 107)
18 - Mechanical wire edge - 6 pieces (code 2077)
(2 pcs on closing, 2 pcs on opening and 2 pcs fixed to the gate post)
230V ±10%
50 Hz
1
2
3
4
2x1mm
2
4x1mm
2
2x1mm
2
4x1.5mm
2
9
5
6
7
8
10
11
12
13
14
15
16
17
2x1mm
2
2x1mm
2
4x1mm
2
4x1mm
2
4x1mm
2
RG58
4x1mm
2
4x1mm
2
18
2x1mm
2
2x1mm
2
2x1mm
2
SYSTEM ELECTRICAL CONNECTIONS
PIC. 21
25
English
230V ±10%
50 Hz
1
2
3
4
2x1mm
2
4x1mm
2
2x1mm
2
4x1,5mm
2
9
5
6
7
8
10
11
12
13
14
15
16
17
2x1mm
2
2x1mm
2
4x1mm
2
4x1mm
2
4x1mm
2
RG58
4x1mm
2
4x1mm
2
18
2x1mm
2
2x1mm
2
2x1mm
2
(cod. 4612)