The maximum power of the machine in the hood type models, will depend on the connection in the
connection strip, as the heating method can be programmed. This may be SIMULTANEOUS or
ALTERNATE, where the boiler and tank resistors operate simultaneously in the first case and the
boiler resistor prevails in the second case. SEE FIGURE.
MOD. D,E
CO, COP, 17x
RC, RT
ALTERNATING
RC, RT
SIMULTANEOUS
7
6
76
The manufacturer will not be held liable for any personal or material damage to the
machine resulting from incorrect installation or failure to comply with the
manufacturer’s specifications.
4.4 Hydraulic connection
The new hoses supplied with the appliance should be used (do not reuse old hoses).
Before connecting the machine to the water supply, the water quality should be tested.
Recommended water quality:
5 – 10 ⁰fH (French degrees)
7 – 14 ⁰eH (English degrees)
9 – 18 ⁰dH (German degrees)
If the water hardness is more than 10 ⁰fH (French degrees), a descaler must be installed.
In addition to water quality, the pressure of the mains water supply must be considered. This is
important to ensure the machine operates correctly.
Required water pressure:
If the water pressure is higher than the recommended pressure, a pressure regulator must be
mounted at the output (SEE FIGURE 3) (page 5). If the mains water pressure is lower than the
recommended pressure, a pressure pump should be mounted at the mains water supply outlet (SEE
FIGURE 4) (page 5). In E models, a pressure pump is not required even when the water pressure is
lower than that stipulated.
FIGURE 3. Direct connection of water input hose.
FIGURE 4. Pressure pump connection.
S → SHUT-OFF COCK F → FILTER H → WATER HOSE
E → ELECTROVALVE B → ELECTRIC PRESSURE PUMP
The following requirements are necessary for the correct hydraulic installation of the machine.
The hydraulic circuit must be fitted with a valve to shut-off the water supply.
Check that the mains pressure is within the range indicated above.
To optimise the working of the machine, the manufacturer recommends that the water
temperature at the machine intake is within the following range.
5 ⁰C < Temp < 35 ⁰C / 41 ⁰F < Temp < 95 ⁰F
50 ⁰C < Temp ≤ 60 ⁰C / 122 ⁰F < Temp < 140 ⁰F
If using hot water, the water temperature must not exceed 60 ⁰C / 140 ⁰F.
If the input water temperature is less than 10 ⁰C, the COLD WATER KIT should be used.
All the machines should have a ¾” screw-on connection.