P0
POSSIBLE FAULTS
F 170A
44
P0 POSSIBLE FAULTS
Many years experience of our product has allowed us to identify and classify
the most common faults which occur. In most cases it requires accurate
hydraulic and electric troubleshooting and simple rectification. In the following
table we report the most frequent inconveniences and our suggested reme-
dies.
(!)
Checking and adjustment of oil pressures of valve settings must be
carried out by an authorized service agent, under penalty of warranty
forfeiture.
P0.1
Operations which can be carried out by the user
FAULTS CAUSE REMEDIES
The crane does not rotate Vehicle non Stabilize the vehicle
properly in level position
Lack of lubrication Grease the bushes and
the rotation guide shoe
The extension booms Lack of lubrication Grease
do not completely extend of the guide shoes the guide shoes
or work jerkily
Crane controls are Lack of Check the fuse,
not active electric energy the battery and
electric circuit
Winch end stroke See
L3.1
active
The rotation limiting device See
H1.7
is activated
Vibrations in Shortage of oil Check the level
crane operations and top up
if necessary
Obstructed filters Clean or replace
the filter cartridge
Noteable decrease in Obstructed filters Clean or replace
movement speed the filter cartridge