Do you have a question about the FATEK FBs-2DA and is the answer not in the manual?
Model | FBs-2DA |
---|---|
Category | Controller |
Type | Analog Output Module |
Number of Channels | 2 |
Output Type | Voltage/Current |
Current Output Range | 0~20mA, 4~20mA |
Resolution | 12-bit |
Power Supply | 24V DC |
Operating Temperature | 0°C ~ 60°C |
Humidity | 5% ~ 95%, non-condensing |
Storage Temperature | -20°C ~ 80°C |
Provides a comprehensive list of FBS PLC models with their item names, model numbers, and specifications.
Lists the technical specifications of the main unit, including execution speed, memory, command types, and register details.
Details Digital I/O and Numeric I/O expansion through units or modules, including system limitations.
Provides precautions for PLC installation, including placement away from noise sources and proper wiring.
Offers guidelines for wiring FBS-PLC, including wire gauge, separation of input/output, and terminal block torque.
Lists specifications and wiring details for AC power supplies like POW-14, POW-24, and FBS-EPOW.
Details specifications and wiring for DC power supplies, including POW-10-D, POW-16-D, and FBS-EPOW-D.
Provides residual capacity for main/expansion units and current consumption of expansion modules.
Details specifications for 5VDC differential and 24VDC single-end inputs, including signal voltage and current.
Details specifications for digital outputs: differential, single-end transistor, relay, and TRIAC outputs.
Covers pre-power-on checks, including cleaning, power type verification, and circuit consistency.
Details the meaning of PLC main unit LED indicators (POW, RUN, ERR, RX, TX) and basic troubleshooting.
Details the allocation of digital elements (X, Y, TR) and register types (TMR, CTR, DR, IR, OR, etc.).
Covers arithmetic operations like 48-BIT DIVISION (FUN23), SUM (FUN24), MEAN (FUN25), SQRT (FUN26).
Covers data movement instructions like BIT READ (FUN40), BIT WRITE (FUN41), BIT MOVE (FUN42), NIBBLE MOVE (FUN43), BYTE MOVE (FUN44).
Explains code conversion instructions: BIN to GRAY (FUN55), GRAY to BIN (FUN56), DECODE (FUN57), ENCODE (FUN58), 7-SEGMENT (FUN59), ASCII (FUN60), HMS (FUN62), HEX (FUN63).
Details I/O instructions: IMMIDIATE I/O (FUN74), DECIMAL- KEY INPUT (FUN76), HEX-KEY INPUT (FUN77), DIGITAL SWITCH INPUT (FUN78), 7-SEGMENT OUTPUT (FUN79).
Covers WATCHDOG TIMER (FUN90) for scan time monitoring and RESET WATCHDOG TIMER (FUN91).
Details HIGH SPEED COUNTER access (FUN92) and VALUE WRITING (FUN93) for HSC0-HSC3 and HSTA.
Describes RAMP FUNCTION FOR D/A OUTPUT (FUN95) for controlling output based on time and preset values.
Covers table operations: MOVE, COPY, COMPARE, SEARCH, FILL, SHIFT, ROTATE, QUEUE, STACK, SORT.
Details NC positioning functions: HSPSO (FUN140), MPARA (FUN141), PSOFF (FUN142), PSCNV (FUN143).
Covers MODBUS MASTER (FUN150) and COMMUNICATION LINK (FUN151) instructions for PLC communication.
Covers floating point operations: Integer to Float (FUN200), Float to Integer (FUN201), ADD (FUN202), SUB (FUN203), MUL (FUN204), DIV (FUN205).