EXAMPLES OF PROGRAMMING
Combination of two Timers.
OPTIONS:
CHARACTERISTICS
DEFAULT PROGRAMMING SETTINGS
Following are several examples of how each
of the 5 Timers can be programmed to obtain
different modalities of functioning.
Indicated for visualizing the time of a
competition with the final audio signal.
To program: xA= Time of Action, xP=0, xC=1
and xF=0.
Indicated for visualizing the time of
competitions repeated on various occasions.
To program: xA= Time of Action, xP= Time of
Pause, xC= Number of cycles, xF=0.
Indicated for continuous sequences of
training; it can be interrupted only by pressing
the key.
To program: xA= Time of Action, xP= Time of
Pause, xC=0, xF=0.
Indicated for training sequences with recovery
times (pause) of differing duration. After the
Final Pause the entire cycle is repeated; it can
be interrupted only by pressing the
key.
To program: xA= Time of Action, xP= Time of
Pause, xC= Number of cycles, xF=Time of
Final Pause.
The activation of a Timer and the booking of
another timer allows to considerably increase
the combinations of the time count. For
example, among the many possibilities, the
count of a certain number of cycles of
Action+Pause may be performed, followed by
a different number of cycles with different
durations ofAction+Pause (see Fig. 2).
The remote control allows to control, without
cables, all of the functions for a distance of up
to 15m. It is not included with the FIGHT
TIMER and can be ordered separately, also at
a later date.
It is possibile to order the practical transport
case for the table version of FIGHT TIMER.
SingleAction
Fixed number of cycles
Infinite number of cycles
Sequences with a fixed Number of cycles and
Final Pause.
START-STOP
START-
STOP
Infrared REMOTE CONTROL (art. 150-02)
CASE (art. 852)
1° Timer 2° Timer
Action
Pause1
5 min 1 min
Action
5 min
Action
5 min
Pause2
1 min
F.Pause
3 min
Action
10 min
Pause1
1 min
Action
10 min
F.Pause
20 min
Fig. 2: Examples of Timer combinations
ENGLISH
Power supply:
Conditions:
Numbers:
Size:
Remote control:
Case:
-2
- functional:
of stocking:
dimension:
visibility:
wall version:
table version:
size:
range:
battery:
-
30 Vac ±10%; 50 Hz; 6VA
- 115 Vac ±10%; 60 Hz; 6 VA
0 .. +50 °C; UR < 95%
- -15 .. +70 °C; UR < 95%
- 9.1 x 4.3 cm
- > 30 m
- 56 x 18.5 x 4.0 cm; 1.6 kg
- 56 x 23 x 18.5 cm;2.1kg
- 4.9 x 11 x 2.2 cm; 0.18 kg
- > 15 m
- 9V; 16 x 45 x 26 mm; 2 years
60 x 40 x 11.4 cm; 2.3 kg
H1 up
H2 2 = Contin.
H3 Sound volume 2 = Middle
1A Timer 1 - 3’:00”
1P Timer 1 - 1’:00”
1C Timer 1 - 6
1F Timer 1 - 0’:00”
2A Timer 2 - 2’:00”
2P Timer 2 - 1’:00”
2C Timer 2 - 3
2F Timer 2 - 0’:00”
Parameter Description Default value
Modality of count
Type of sound
Time of action
Time of pause
Number of cycles
Time of Final Pause
Time of action
Time of pause
Number of cycles
Time of Final Pause
6