FGP฀50/M฀EVO
TECHNICAL฀DATA฀FGP฀50/M฀EVO
OPERATING฀RANGE฀DIAGRAM฀FGP฀50/M฀EVO
Fig. 2 X฀=฀Thermal฀power฀Y฀=฀Pression฀in฀the฀combustion฀chamber
The฀firing฀rates฀has฀been฀obtained฀based฀on฀test฀boilers฀in฀accordance฀with฀EN267฀standards฀and฀are฀indicative฀of฀matching฀the฀burner฀to฀the฀
boiler.฀For฀the฀correct฀operation฀of฀the฀burner,฀combustion฀chamber฀dimensions฀must฀be฀in฀accordance฀with฀current฀regulation.฀In฀case฀of฀non-
compliance,฀contact฀the฀manufacturer.
-1
1
3
5
7
9
11
13
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
<kW>
<mbar>
)*30(92
*Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level).
MODEL
FGP฀50/M฀EVO
Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀*[Mcal/h]107/204-542
Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀*[kW]124/237-630
LIGHT-OIL฀flow฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀*[kg/h]10.5/20-53
Fuel:LIGHT-OIL฀1.5°E฀at฀20°C฀=฀6.2฀cSt฀=฀35฀sec฀Redwood฀N°1
Intermitted฀working฀operation฀(min.฀1฀stop฀every฀24฀hours)฀two฀stages฀progressive฀or฀modulating
Environmental฀conditions฀operation฀/฀storage:-15...+40°C฀/฀-20...+70°C,฀rel.฀humidity฀max.฀80%
Max.฀temperature฀combustion฀air[°C]60
Nominal฀electric฀power[kW]1.1
Fan฀motor[kW]0.55
Pump฀motor[kW]0.37
Nominal฀fan฀motor฀current฀absorption[A]1.4
Nominal฀pump฀motor฀current฀absorption[A]1.2
Nominal฀auxiliary฀absorption[A]0.6
Power฀supply:3~400V,1/N~230V-50Hz
Electric฀protection฀degree:IP44
LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀