EasyManua.ls Logo

FBR FGP 50/M EVO - FGP 50;M EVO Product Specification and Compliance; Detailed Product Specifications; Regulatory Compliance and Standards; Included and Optional Equipment

FBR FGP 50/M EVO
6 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SK070003_A_gb
FGP฀50/M฀EVO
PRODUCT฀SPECIFICATION
SHORT฀DESCRIPTION
Light-oil฀burners฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀
addition฀of฀optional฀modulation฀kit฀and฀probe.
DETAILED฀SPECIFICATION
Light-oil฀burner฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀addition฀
of฀optional฀modulation฀kit฀and฀probe;฀composed฀by:
•Fan฀at฀high฀pressurisation฀at฀reverse฀blades;
•Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability;
•Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler;
•Three-phase฀power฀supply;
•Photodiode฀for฀flame฀detection;
•IP฀44฀electric฀protection฀level;
•Servomotor฀for฀air฀shutter฀and฀for฀the฀pressure฀regulator;
•Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier;
•Maximum฀light-oil฀pressure฀switch฀to฀stop฀the฀burner฀in฀case฀of฀the฀light-oil฀pressure฀on฀the฀return฀is฀higher฀then฀the฀set฀point
value;
•Safety฀air฀pressure฀switch฀to฀stop฀the฀burner฀in฀lock-out฀(by฀stopping฀the฀pump฀motor)฀in฀case฀of฀failed฀or฀anomalous฀fan
operation;
•Dedicated฀motor฀for฀the฀activation฀of฀the฀light-oil฀pump;
•Set฀up฀for฀the฀additional฀specific฀kit฀that฀transforms฀burner฀operation฀as฀modulating฀i.e.฀the฀modulating฀kit฀allows฀to฀supply
any฀power฀between฀the฀minimun฀and฀the฀maximum฀value฀based฀on฀instantaneous฀loading฀request.
CONFORMING฀TO:
•CE฀rules;
•2014/30/UE฀Directive฀E.M.C.;
•2014/35/UE฀Directive฀L.V.;
•2006/42/CE฀-฀2006/42/EG฀-฀2006/42/EC฀Directive฀M.D.;
•Directive฀PED฀2014/68/UE฀(ART.4,PAR.3);
•Reference฀rules:฀EN267฀(liquid฀fuel)฀-฀EN746-2฀(industrial฀thermoprocessing฀equipment).
STANDARD฀EQUIPMENT
OPTIONAL
•Power฀modulating฀kits฀for฀temperatures;
•Power฀modulating฀kits฀for฀pressures;
•Temperature฀probe฀0°C-400°C฀(PT฀100฀a฀0°฀C);
•Temperature฀probe฀0°C-350°C฀(J฀probe);
•Temperature฀probe฀0°C-1200°C฀(K฀probe);
•Pressure฀probe฀0-3฀bar,฀0-6฀bar.฀0-16฀bar,฀0-20฀bar,฀0-30฀bar;
•Noise฀protection.
The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products.
LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀
OR฀MODULATING
•Flexiblehosesforconnection;
•Linefilter;
•Isomartgasket;
•Nozzle;
•Flangewithinsulatinggasket;
•Burnernameplate;
•Warranty;
•Instructionhandbookforinstallation,useandmaintenance.