Questions and Answers

  • C
    Christian CohenAug 20, 2025
    What to do if FE PXR5 Microcontrollers are not controlling properly?
    • M
      Michael Crawford DDSAug 20, 2025
      If your FE Microcontroller isn't controlling properly, it might be because the set values of the parameters P and are incorrect; try performing the auto-tuning. If the cycle times are too long, decrease the set value of the parameters and gradually. If the output is limited, set the parameters of, and again to be suitable for the process. If the output is not limited correctly, set the parameters of again to be suitable for the process.
  • N
    Nicholas MartinezAug 22, 2025
    Why is auto-tuning not working on my FE PXR5?
    • C
      cmurrayAug 23, 2025
      If auto-tuning isn't working properly on your FE Microcontroller, it could be due to several reasons. If the display shows or after starting the auto-tuning operation, set the parameters again so that the difference of the set values of and is made larger, and then perform the auto-tuning again. If you changed the SV after starting auto-tuning, set the desired SV and repeat the auto-tuning. Also, if you attempted auto-tuning during ramp-soak operation, set the parameter to and try again. Ensure that peripheral devices are properly connected. If the response of the controlled device was too fast, use a controller whose control cycle is fast, such as PYH.
  • D
    danapattersonAug 26, 2025
    How to fix SV if it cannot be changed on FE PXR5?
    • J
      Justin Spears DVMAug 26, 2025
      If the SV on your FE Microcontroller cannot be changed, it might be because is set to “1” or “4” in the parameter; set the parameter to “0”, “2”, “3” or “5”. Another reason could be that you're trying to set a value outside the SV limiter; widen the range of to , ensuring it remains within the set range in the input range table.
  • D
    Diana TurnerAug 28, 2025
    What to do if ON/OFF control has not functioned properly on FE PXR5?
    • R
      Robert HolmesAug 28, 2025
      If the ON/OFF control on your FE Microcontroller isn't functioning properly, it could be because the set value of parameter is not correct; adjust the set value of parameter to be suitable for the device to be controlled. Alternatively, the setting of parameter might be incorrect; set the parameter correctly.
  • L
    Leslie MacdonaldAug 30, 2025
    Why are parameters not displayed on my FE PXR5 Microcontrollers?
    • J
      Julie StewartAug 30, 2025
      If the parameters you wish to confirm or change are not displayed on your FE Microcontroller, it might be because the concerned parameters are set to skip in the parameters of to . To resolve this, change the set value of the concerned dSP.
  • B
    Brittany RiceSep 2, 2025
    Why is the response too slow on my FE PXR5?
    • J
      Jasmine MillerSep 2, 2025
      If the response of your FE Microcontroller is too slow, meaning the measured value changes slowly, the input filter constant might be too large. Try decreasing the set value of the parameter .
  • J
    Jessica HunterSep 4, 2025
    What to do if keys do not operate on FE Microcontrollers?
    • G
      gabriel15Sep 4, 2025
      If the keys on your FE Microcontroller do not operate and you cannot change the set value of the parameters, it might be because “1”, “2”, “4”, or “5” is set in the parameter . To fix this, set the parameter to “0” or “3”.
  • E
    Emily RuizSep 6, 2025
    Why are SV or parameters changing on FE PXR5 without operation?
    • L
      Larry RichSep 6, 2025
      If the SV or set values of some parameters on your FE Microcontroller have changed without any operation, it could be because the parameter was changed. To resolve this, set all the parameters again. Also, if the set value of is larger than 1000, set to “0” and return to an original value.
  • R
    rmillerSep 9, 2025
    What to do if an excessive over-shoot occurs during auto-tuning on FE PXR5?
    • B
      Brett JonesSep 9, 2025
      If an excessive over-shoot has occurred during auto-tuning operation on your FE Microcontroller: (1) Perform the auto-tuning with the parameter of being “2” (Low PV type). (2) Perform the tuning manually.
  • B
    Brooke NelsonSep 12, 2025
    What to do if ON/OFF control has not started on FE PXR5 Microcontrollers?
    • S
      stevencarterSep 12, 2025
      If ON/OFF control (Two-position control) has not started on your FE Microcontroller, ensure that 0.0 is set in the parameter . If not, set the parameter to 0.0.

Summary

Part Names and Functions

Operations

Parameter List

Lists all parameters with their settings, ranges, and cross-references to pages.

Basic Operations

Explains fundamental operations like changing parameters, setting values, and mode switching.

Parameter Functions and Method of Settings

Details specific parameter functions and provides step-by-step guides for their configuration.

Manual Mode Setting

Standby Setting

Local;Remote Operation Setting

Ramp-Soak Control

Auto-Tuning Function

Alarm Settings (Alarm 1, 2, and 3)

Proportional Band Setting

Integral Time Setting

Derivative Time Setting

Hysteresis Range for ON;OFF Control

Control Algorithm Selection

Self-Tuning Functionality

Hysteresis Mode for ON;OFF Control

Input Signal Code Selection

Measuring Range and Unit Settings

Alarm Type Configuration

Ramp-Soak Pattern Selection

Ramp-Soak Status and Parameters

Burn-out Output Specification

SV Limiters

SV Lower Limiter

Sets the lower limit for the Setting Value (SV) to constrain its range.

Alarm Hysteresis Settings

Control Output Limits

PV Display Adjustment (Zero Point)

Digital Input (DI) Operations

Retransmission Scale Settings

Remote SV Input Adjustment

Troubleshooting

Safety Precautions

Over-temperature Protection

Addresses risks of unwanted continued heating and system design considerations.