Scooterpac Feather Fold | User Manual 30
16 Fl a s h Co d e s
The diagnostic flash codes for your scooter are designed to help you perform basic troubleshooting quickly and easily. A
diagnostic flash code flashes from the power light in the event one of the conditions listed below develops.
1-5 * *****
Battery charge is too low or
bad connection
2. Check all battery wiring connections.
3-2 *** ** Brake error
1. Ensure the manual freewheel lever is in the
drive position and restart the scooter
2. There is a fault with the electromagnetic
brake or wiring
1-2 * **
Throttle pot error
Open circuit
1. The throttle pot or it’s wiring could be faulty
2. The speed pot or it’s wiring could be faulty
2-5 ** *****
Throttle pot error
Short circuit
1. The throttle pot or it’s wiring could be faulty
2. The speed pot or it’s wiring could be faulty
1-6 * ******
Throttle control lever not at
centre position when
switching scooter on
1. Put the throttle control lever in the central
position, turn the power off and turn on
again.
2. Check that the charger is not connected
1-3 * *** Charge inhibited
1. Check the charger and charging socket
2. Contact your Dealer