EasyManuals Logo

Federal Signal Corporation SSP2000B User Manual

Federal Signal Corporation SSP2000B
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BLUE 18 AWG
100 W (SSP2000B/SSP3000B)
200 W (SSP3000B ONLY)
BROWN 18 AWG
SERIAL PORTS
10 8 6
4
2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 12 2 3 4
AUX
PARK
INPUT
+12V
+
P
RADIO
RING
SPKR
DO NOT EXCEED 5 AMPS
MAXIMUM ON HORN RING
CIRCUIT. SEE INSTALLATION
INSTRUCTIONS
RADIO
RING
SPKR
RADIO
RING
SPKR
RADIO
RING
SPKR
SM
Quick Connect Guide: SSP3000B/SSP2000B System Wiring Connections
25500152 REV. A0 1014
SERIAL PORTS: Connect
up to two Federal Signal
serially-controlled devices.
SPEAKERS: Two are
connected in parallel
and in phase (SSP3000B).
SSP2000B has only one
speaker.
For details, see the "SmartSiren Platinum Series Installation, Maintenance,
and Service Manual" (P/N 25500151) and the "Convergence Network
Conguration Software Manual" (P/N 2562418).
MICROPHONE
(P/N 258B577-03)
SM
1
SM
2
SM
3
SM
4
SM
5
SM
6
SM
7
SM
8
8-HEAD
S
IGNALMASTER
6-HEAD
S
IGNALMASTER
SM POWER OUT (20 A
FUSE ON TOP OF SIREN)
11 12 13 14 1 2 3 4
AUX. RELAYS INPUTS
WHITE
BROWN
GREEN
ORANGE
VIOLET
YELLOW
GRAY
BLUE
WHT/RED
WHT/ORG
WHT/YEL
WHT/BLU
WHT/BRN
WHT/GRN
WHT/VLT
WHT/GRY
SM SM SM SM SM SM
1 2 3 4 5 6
20 AWG
RED 18 AWG
BLACK
AUX. RELAYS 11-14:
2
A solid-state relays
are 12
Vdc out only.
For these two connectors
(P/N 1751541 and P/N 1751542-01)
see the enlarged detail on the right.
RELAY CABLE ASSY.
(P/N 1751541)
10 8 6 4 2
9 7 5 3 1
WHITE
BROWN
GREEN
BLUE
RED
ORANGE
YELLOW
VIOLET
GRAY
BLACK
18 AWG
AUX. RELAY 1–10:
10 A solid-state relays 9/10
can be congured as 12 Vdc
out or ground out. Relays 1-8
are 12 Vdc out. The SSP2000B
has only relays 1-6 and 10.
INPUTS 1–2:
Apply ground
to activate.
INPUTS 3–4:
Apply 12 Vdc
to activate.
PARK INPUT (BLACK):
Sends a signal to the siren
amplier that:
mutes all siren tones except
Air Horn and Manual
OR
disables white ashing lights
when the vehicle transmission
is shifted into park or neutral.
HORN RING: Enables the
step-through selection of
siren tones each time the
horn ring is pressed while
the control of the tone is
transferred.
Back of SSP3000B Siren Amplier / Relay Module
FS ConvergenCe
NETWORK
CONNECTIONS
(to serially-
controlled devices)
ACTIVE-LOW INPUTS 1-4:
Ground-activated. Can be
programmed to activate with the
control pad, installer-supplied
switches (current capacity of
100 mA each), or with the two-
position switches on the steering
wheel of the Ford Police Interceptor.
RADIO: Rebroadcasts
incoming radio messages
through the siren speakers.
6-PIN CABLE ASSY.
(P/N 17500307):
See connector detail below.
BLACK
RED
INPUT 4 (BLUE)
INPUT 3 (PURPLE)
INPUT 2 (WHITE/YELLOW)
INPUT 1 (GRAY)
TO -GND
TO +12 V CONNECTION
ACTIVATED BY IGNITION (OR
TO +BAT IF THE IGNITION
TIMER FUNCTION IS USED)
IGNITION INPUT (YELLOW)
IF THE IGNITION TIMER
FUNCTION IS USED
22 AWG
FS ConvergenCe NETWORK CONNECTION
CABLE, 25 FEET LONG (P/N 1751357-02)
ETHERNET
CABLE ASSY.
(P/N 1751532)
CONTROL PAD CABLE
ASSY. (P/N 17500308)
Computer for the
software conguration
of the siren system.
SignalMaSter™, RELAY and INPUTS
CABLE ASSY. (P/N 1751542-01)
+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Federal Signal Corporation SSP2000B and is the answer not in the manual?

Federal Signal Corporation SSP2000B Specifications

General IconGeneral
BrandFederal Signal Corporation
ModelSSP2000B
CategoryControl Unit
LanguageEnglish

Related product manuals