12
TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
• Saw won’t start • Loss of power supply • Check power source
• Brushes worn or sticking • Check brushes
• Switch is faulty • Contact repair center
• Possible short circuit • Contact repair center
• Cord damaged • Contact repair center
• Unsatisfactory cuts • Dull, damaged or incorrect blade • Sharpen or replace blade
• Motor is overloaded. • Reduce pushing force
• Unusual sound • Mechanical obstruction. • Contact repair center
• Possible short circuit • Contact repair center
• Blade out of balance • Replace blade
• Heavy sparking inside
motor housing
• Brush not moving freely • Disconnect power, remove
brushes and clean or replace
• Possible short circuit/dirty
commutator
• Contact repair center
SPECIFICATONS:
Rated voltage 110-120V~ 50/60Hz 220-240V~ 50/60Hz
Rated input 1800W
No load speed 2300min
-1
(RPM)
Arbor 15.9mm
Saw blade diameter 230mm(9")
Arm-held vibration 6.75m/s2 k=1.5
Weight 9.5kg
Max. cutting depth at 90
83mm
Max. cutting depth at 45
56.5mm
Max. cutting thickness 13mm
Sound power level 95.5 dB(A)
Sound pressure level 93.8 dB(A)