FERtech F 24 D - F 32 D
F 24 D
F 32 D
700
400
330
85
115
91
109
195
266
80
80.5
51
54
76
58.5
178
126
ABCDEF
330
Ø
110
÷
120
120
725.5
676.5
50 76 54 51 80.5 74.5
93
114
Ø
30
Ø
30
Ø
24.5
Ø
24.5
Ø
24.5
FABCD E
85
115
115
85
195
330
A
B
C
D
E
F
IT -
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
RU -
ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ

Questions and Answers

  • C
    Clarence ColemanAug 21, 2025
    What to do if my Fer FERtech F 32 D Boiler has no burner ignition?
    • N
      Nicole BlairAug 22, 2025
      If your Fer Boiler fails to ignite, several factors could be at play. First, ensure that there is a regular gas flow to the boiler and that the air has been eliminated from the pipes. Next, check the wiring of the ignition/detection electrode, ensuring it's correctly positioned and free of deposits. Also, the gas valve might be faulty, so inspect it and replace if necessary. Furthermore, make sure the gas valve wiring is connected. Finally, the ignition power might be too low, so adjust it accordingly.
  • J
    James FrancoSep 4, 2025
    What does it mean if my Fer FERtech F 32 D has a Delivery sensor 1 fault?
    • F
      fcooperSep 4, 2025
      A Delivery sensor 1 fault in your Fer Boiler may be due to a damaged sensor. Check the wiring or replace the sensor. It could also be due to wiring shorted or wiring disconnected.
  • A
    aallenSep 2, 2025
    What to do if my Fer FERtech F 32 D shows a fan fault?
    • T
      Tiffany CookSep 3, 2025
      If your Fer Boiler indicates a fan fault, start by checking the wiring to ensure it is properly connected. If the wiring is intact, the fan itself may be defective, requiring a check of the fan. Alternatively, the card could be faulty, necessitating a check of the card.
  • C
    Christine SimmonsSep 1, 2025
    What to do if my Fer FERtech F 32 D Boiler has exchanger protection trips?
    • D
      David BoydSep 1, 2025
      If your Fer Boiler's exchanger protection trips, it could be due to no HO system circulation. Check the circulating pump. Another possible cause is air in the system, so vent the system.
  • J
    Justin HarveyAug 30, 2025
    What to do if my Fer Boiler is showing a flame present signal with burner off?
    • K
      Krystal MolinaAug 30, 2025
      If your Fer Boiler shows a flame present signal even when the burner is off, it could indicate an electrode fault. In this case, check the ionisation electrode wiring. Another possibility is a card fault, which would require checking the card.
  • R
    raymond91Aug 29, 2025
    What to do if my Fer FERtech F 32 D Boiler shows a combustion control fault?
    • P
      Peter NovakAug 29, 2025
      If your Fer Boiler displays a combustion control fault, it could be related to a fan fault. In this case, check the fan and fan wiring. Alternatively, a faulty baffle or a flue that is not correctly sized or is obstructed could be the cause. Check the baffle and replace it if necessary, and check the flue.
  • M
    michellecarterAug 27, 2025
    What to do if my Fer Boiler has poor combustion fault?
    • H
      holtnicholasAug 28, 2025
      If your Fer Boiler shows a poor combustion fault, specifically if fault F20 was generated 6 times in the last 10 minutes, refer to fault F20 for guidance.
  • R
    ritterphilipAug 27, 2025
    What to do if my Fer FERtech F 32 D has poor combustion?
    • K
      Kim SimpsonAug 27, 2025
      If your Fer Boiler is experiencing poor combustion, it might be due to an inlet/exhaust flue obstruction. To resolve this, check the flue.
  • A
    Andrew OdonnellAug 25, 2025
    What to do if my Fer Boiler activates overtemperature protection?
    • R
      Roger KennedyAug 26, 2025
      If your Fer Boiler activates overtemperature protection, it may be due to a damaged heating sensor. Check the correct positioning and operation of the heating sensor. It could also be caused by no water circulation in the system, so check the circulating pump. Finally, air in the system can trigger this, so vent the system.
  • V
    Veronica ColonAug 23, 2025
    Why is my Fer FERtech F 32 D showing a gas valve fault?
    • J
      Jose KingAug 23, 2025
      A gas valve fault in your Fer Boiler can arise from modulating operator wiring disconnected, requiring a check of the wiring. Alternatively, it might be due to a faulty gas valve, necessitating a check and potential replacement of the valve.

Summary

General Warnings

Installation Procedures

General Installation Guidelines

General guidelines for boiler installation by qualified personnel.

Selecting the Installation Location

Recommendations for choosing a suitable installation site.

Connections and System Requirements

Gas and Electrical Connections

Instructions for gas supply and electrical connections, including earthing.

Fume Ducting and Ventilation

Service and Maintenance Overview

Boiler Adjustments

Instructions for gas type, TEST mode, and burner pressure adjustments.

Boiler Startup Procedure

Steps for initial boiler startup and operational checks.

Burner Pressure Adjustment

Periodic Maintenance and Troubleshooting

Scheduled Maintenance Checks

Annual maintenance tasks for ensuring continued operation.

Fault Diagnosis System

Explanation of the self-diagnosis system and fault code interpretation.

Technical Data and Characteristics

Technical Data Tables and Diagrams

Fer FERtech F 32 D Specifications

General IconGeneral
BrandFer
ModelFERtech F 32 D
CategoryBoiler
LanguageEnglish

Related product manuals