ECC+ 230 V Electronic Module
24 / 25 / 26 Safety switch.
Serial switch connection. Direct connection between the entrance and the exit without
any inuence in the electrical circuit function.
27 / 28 / 29 / 30
Reopen.
These connections are in series and are normally closed. These inputs are used to connect
a light curtain, the cabin push-button or any other device that initiates the reopening
process when the door starts to close. It does not activate when the door is closed. If
these inputs are not used it is necessary to bridge them.
31 / 32 Limit switch with encoder.
With DIP-switch No. 1 switched to ON it is necessary to install a close limit switch. The
open position is given by the motor encoder.
33 / 34 / 35 / 36
Limit switch without encoder.
With DIP-switch No. 1 switched to OFF it is necessary to install both an open and close
limit switch.
37 Motor and encoder.
Output to the 24 V DC motor to control speed and torque. The ECC+ 230 V motor controller
is formed by a power stage with a current limiting protection.
The 24 V DC motor incorporates a thermal protection in order to inform the lift controller
in case of motor overheating. Once the thermal protection is activated, the lift control has
to remove immediately the open/close input to stop the motor and allow it to cool down.
38 Test pushbutton.
Operation of the Test pushbutton will cause a door open or close cycle.
39 Safety.
This potentiometer is used to set the closing force over an obstacle in the clear opening.
40 Close speed.
The door closing speed can be independently adjusted.
41 Open speed.
The door closing speed can be independently adjusted.
42 On / Off switch.
Disconnects the unit from the 230 V AC mains supply.
45 Com port.
The serial port is used to connect with external devices, interfaces and
future expansion devices. Operating speed 1.200 Baud per second,
current loop.
In this section the modications are listed to provide customer awareness in order to comply with the new
lift standard EN 81-20.
LIGHT CURTAIN
· The light curtain is mandatory and has to be connected to the lift controller.
INPUTS
45
PUERTO SERIE
SERIAL PORT
LIFT STANDARD EN 81-20