ENG
User manual.
Automatic horizontal sliding car door.
Component: VF7 Electronic Module. V7.01.02.
MAN-MU00000V7ENGTC-12.2017
Question and Answer IconNeed help?

Do you have a question about the Fermator VF7 and is the answer not in the manual?

Fermator VF7 Specifications

General IconGeneral
BrandFermator
ModelVF7
CategoryControl Unit
LanguageEnglish

Summary

User Manual Overview

Product Identification

Identifies the product as the VF7 Electronic Module for automatic horizontal sliding car doors.

Electrical Connections

Power Supply and Motor Connection

Details the connections for power supply and the motor, including voltage inputs.

Input and Output Terminals

Illustrates the various input and output terminals for signals and power on the VF7 module.

Power Supply and Basic Inputs

Power Supply Requirements

Specifies the main supply voltage (230 VAC) and frequency requirements for the VF7 module.

Input Signal Configurations

Explains external and internal voltage inputs for open, close, common, and 0V signals.

Advanced Inputs and Signals

Open Signal and Communication Port

Details the open signal input and the serial communication port for external devices.

Priority Inputs and Photocell

Describes priority inputs like Re-open, Light Curtain, and the +12V output for activation.

Additional Inputs and Output Indicators

Special Function Inputs

Explains inputs for bypass contact, slow closing, and floor level emergency power.

Output Relays and LED Status

Details output relays and LEDs for door status: Open, Closed, Photocell, Obstruction, Light Curtain, Temperature.

Motor Interface and Graphic Control

Encoder and Motor Connections

Details the encoder input for position/speed and the motor output for speed/torque control.

VF7 Graphic Interface Introduction

Outlines the main objectives and navigation of the VF7 graphic interface for monitoring and configuration.

Alarm Management System

Alarm Menu Overview

Displays the last five activated alarms, allowing users to view and acknowledge them.

Specific Alarm Troubleshooting

Details common alarms like Short-C, Current, Low Volt, Memory, Friction, Belt, Encoder, with causes and solutions.

Advanced Alarm Handling

Obstruction and Calibration Alarms

Covers alarms related to obstructions, calibration failures, and motor/module temperature issues.

Temperature and Referencing Alarms

Details temperature-related alarms and referencing issues, including their resolution.

Real-time Monitoring Menu

Monitor Menu Navigation

Explains how to navigate the Monitor Menu to view real-time VF7 parameters.

Parameter Categories Overview

Lists categories like Parameters, Outputs, Counters, Motor, Inputs, and Information for monitoring.

Detailed Monitoring Parameters

Door and Motor Monitoring Details

Provides specific parameters for monitoring door status, position, speed, voltage, and motor temperature.

Input/Output and Counter Monitoring

Details monitoring of input/output signals, status, and counter values for door operations.

System Counters and Information

Counters and System Information

Details door cycle counts, power-ups, errors, and system information like software/hardware versions.

Programming Menu Introduction

Introduces the Programming Menu for modifying VF7 internal parameters and options.

Parameter Configuration

Program Options and Parameters

Covers basic options, interact settings, input logic, functions, and parameter groups like speeds and lengths.

Modifying Parameters

Provides a step-by-step guide on how to select, modify, and save parameter values.

Programming Options Details

Door Model and Control Settings

Configures door model (T1-C8), control mode (Master/Slave), and landing door type (Automatic/Semiautomatic).

Input Configuration Options

Explains how to configure single or dual input modes for door control signals.

Interactive Programming Options

Input Logic and Signal Handling

Configures priority inputs, keyboard shortcuts, and specific signal behaviors like slow close and bypass.

Door Behavior Options

Details options for door anticipation, bypass signals, curtain error handling, and DPM system.

Input Logic and Functional Options

Negative Logic Inputs

Configuration for normally closed (NC) contacts for various input signals like Open, Close, and Curtain.

Functional Configuration Options

Sets up Eco Mode, CDL, Security Device, Barrier Timer, Temperature, Energy Limit, and other advanced functions.

Speed Profiles and Calibration

Speed Profile Diagrams

Visual representation of open and close speed profiles, illustrating key speed and length parameters.

General and Speed Parameters

Details parameters for door mass, clutch mass, gear ratio, and various opening/closing speeds and accelerations.

Motor Calibration Process

Explains the one-time motor calibration process to detect electrical characteristics for optimal performance.

Length, Torque, Time Parameters & Control

Length, Torque, and Time Settings

Defines parameters for door lengths, torques (open, close, hold), and time delays (Eco, Backstep).

Test and Door Learning Procedures

Details how to perform a test cycle and the crucial door learning/autoadjustment process.

System Settings and Installation Start

Settings Menu Options

Allows configuration of language, display, factory settings, and password protection for the VF7.

Initial Installation Steps

Details essential connections like motor, encoder, photocell, and power supply for initial setup.

Installation and Power Failure Features

Configuration and Connection Steps

Guides on programming door type, landing type, rotation sense, control behavior, and connecting cables.

Power Failure Safeguards

Explains the anti-banging system and electronic car door lock features for power failure scenarios.

Lift Standards and Safety Features

Electronic Car Door Lock Functionality

Details how the electronic car door lock operates during power failures and can be enabled/disabled.

EN 81-20/50 Compliance

Outlines requirements for kinetic energy, door model, and light curtain settings to meet EN 81-20/50 standards.

Compliance and Reference Data

Kinetic Energy and Overheating Protection

Explains kinetic energy limits and how overheating protection is managed via temperature measurement.

Reference Data for System Components

Provides technical specifications for power supply, inverter, inputs, and positional control.

Output Performance and Product Lines

Output Specifications

Details switched contacts, contact rating, switch time, output current, and voltage.

Compact Product Line Data

Provides moving mass data and multiplier factors for the Compact product line based on panel type and fire homologation.

Product Line Data (40/10 & Premium)

40/10 Product Line Multipliers

Lists multiplier factors for the 40/10 product line based on differences in model, opening, and panel specifications.

Premium Product Line Multipliers

Provides multiplier factors for the Premium product line for various configuration differences.

Platinum Product Line & Example Calculation

Platinum Product Line Data

Lists moving mass and multiplier factors for the Platinum product line.

Example Calculation: PL and HL Increment

Demonstrates calculation of moving mass increment based on PL and HL changes for the 40/10 PM model.

Example Calculation: Panel & PL/HL Differences

Example 2 Calculation Details

Shows calculation of moving mass involving opening, panel count, PL, and HL differences for Premium PM.

Declaration of Conformity

Product Compliance Statement

Declares that the VF7 Electronic Module conforms to relevant EU directives and standards.

Important Notices and Contact Information

Modification and Liability Disclaimer

Advises on modifications, liability for incorrect installation, and the right to change specifications.