MONITOR MENU
Monitor Motor
Parameter Description Units
Speed Motor speed (m/s). mm/s
Voltage Tension that the circuit applies to the motor (V). V (RMS)
RMS Current Output current (A). A
Motor Type Motor connected to the circuit. -
Temperature Temperature in the PM motor (Temperature measurement option has to be
enabled).
ºC
Monitor Inputs
Parameter Description Units
Open Status of the open signal. -
Close Status of the close signal. -
Re-open Status of the re-open signal. -
Floor Status of the oor level signal. -
Slow Close Status of the slow close signal. -
Bypass Status of the Close Position signal. -
Curtain error Status of the curtain error. -
Monitor Outputs
Parameter Description Units
Open Door Status of the door open signal. -
Closed Door Status of the door closed signal. -
Re-open Status of the Re-open signal. -
Obstruction Status of the obstruction signal. -
Curtain Error Status of the light curtain signal. -
Temperature Error Status of the temperature signal. -
Monitor Door
Parameter Description Units
Position Position of the door in m, indicating the zero point with the door closed and the clear
opening + Clutch length with the door open.
m
Status Status of the door (Door closed, Door opened, Closing door, ...). -
CDL Door with Car Door Lock (automatic detection during autoadjustment). -
Friction Friction value detected during the autoadjustment. Frictionless door when this
parameter is 0.
Scaled from 0 to 150
Bypass Length The distance from closed door position to open bypass contact detected during the
learning process.
m