Cod. 970030 V04_20
8
Change access mode
Activate or deactivate the door sensor and adjust acoustic and visual response. All in ON by default
Activate or deactivate the Alarm.
Restore default values (Users are not removed) and master cards programming.
1. Switch off the device.
2. Connect GND and Bs.
3. Switch on the device.
4. You will hear 2 beeps, the LED changes to another more orange tone. 2 Options:
1. PROGRAMMING MASTER CARDS: Remove the bridge or stop pressing the exit button and present
two cards, it will be the 1st master Add and the 2nd master Delete.
2. RESTORE DEFAULT VALUES. Keep the bridge between GND and Bs or the Exit button pressed for at
least 10 seconds more until you hear a beep, and see that it returns to standby, it is restored to the
factory settings.
Maintenance
FACTORS INFLUENCING THE OPERATING DISTANCE
Orientation of the proximity key. Faulty reader supply. Interference on the 125khz and 13.56 MHz band.
CE DECLARATION OF CONFORMITY
Hereby, FERMAX ELECTRONICA, S.A.U., declares that this KEYPAD RESISTANT REF. 5293, is in compliance with the
essential requirements of Directive RED 2014/53/UE and Directive RoHS 2011/65/UE. See website
www.fermax.com. FERMAX Avd. Tres Cruces, 133, 46017 Valencia, Spain.
http://docweb2.fermax.com/docs/deconformidad/EN/F05293.pdf