32 DUOX PLUS WIFI VEO XS MONITOR
Notes:
- Auto-on only works with suitable panels. If you are unable to effect auto-on, please consult
your installer. If it is unable to connect to any of the three possible panels, the monitor
will issue an error tone and return to its idle state.
- Once a conversation with a panel is over, pressing the auto-on button within the following
15 seconds will reconnect you to that panel.
- In the case of auto-on without audio, if the door is opened within 5 seconds, the call will end.
• Various cases of a second monitor performing an auto-on can be distinguished:
o The rst monitor is in auto-on mode, and has not established a conversation with audio:
in this case, the second monitor cannot perform an auto-on.
o The rst monitor has performed an auto-on and has established an audio conversation:
the auto-on can begin.
o In any case, when the rst monitor’s conversation or auto-on with video only ends, the
second monitor may perform an auto-on.
Auto-on in incoming call state:
1. If the call corresponds to a panel in the sequence described in the previous point,
the auto-on will begin for the next panel in the sequence.
2. If the call is NOT from a panel, auto-on will begin with block panel 0, (depending on
panel availability), and follow the sequence:
0 1
G
1
Panel 0 or camera 0 of the
monitor block
2
Panel 1 or camera 1 of the
monitor block
3
Panel 0 or camera 0 of the
General Entrance

Related product manuals