8. CHARACTERISTICS TABLE
Model
No.
elements
Power
(W)
A
(mm)
Weight
(kg)
Voltage
(VAC)
Class
Index of
protection
Type of
radiator
RIMINI DP 50 3 500 396 6,4
230 V ~
50 Hz
I IP2X Fluid
RIMINI DP 75 5 750 556 9
RIMINI DP 100
6 1000 636 10,5
RIMINI DP 120 7 1200 716 11,9
RIMINI DP 150
9 1500 876 14,6
100
A
581
9. ECODESIGN TABLE
Models
RIMINI DP
50
RIMINI DP
750
RIMINI DP
100
RIMINI DP
120
RIMINI DP
150
Heat output
Nominal heat output (P
nom
) 0,5 kW 0,8 kW 1,0 kW 1,2 kW 1,5 kW
Maximum continuous heat output (P
max,c
) 0,5 kW 0,75 kW 1,0 kW 1,2 kW 1,5 kW
Auxiliary electricity consumption
At nominal heat output (el
max
) 0,5041 kW 0,7555 kW 1,0068 kW 1,2082 kW 1,5099 kW
At minimum heat output (el
min
) 0,5041 kW 0,7555 kW 1,0068 kW 1,2082 kW 1,5099 kW
In standby mode (el
SB
) 0,0013 kW
Type of heat output/room temperature control Electronic room temperature control plus week timer
Other control options
Room temperature control, with open window detection
With adaptive start control