EasyManua.ls Logo

Festo CPX-AP-I - User Manual

Festo CPX-AP-I
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CPX-AP-I
Automation system
Operating instruc-
tions
8168784
2022-06a
[8168786]
Question and Answer IconNeed help?

Do you have a question about the Festo CPX-AP-I and is the answer not in the manual?

Summary

About This Document

Document Information

Covers applicable documents, product version, labelling, and specified standards.

Safety Guidelines

Safety Instructions, Intended Use, and UL Certification

Details safety rules, intended use, personnel qualifications, and UL certification.

Product Overview

Functionality and Structure

Describes the CPX-AP-I system, its function, structure, and variants.

Module Types

Details interface, input/output, and electrical interface modules with their functions.

LED Displays and Labelling

Explains LED displays for status and diagnostics, and module labelling elements.

System Communication and Assembly

System Communication and Addressing

Explains internal module communication, addressing, and data exchange.

Assembly and Mounting

Covers mounting distances, installation space, and direct mounting procedures.

Installation Procedures

Power Supply Concepts

Details power supply configurations, including logic and load supplies.

Voltage Drop and Electrical Isolation

Addresses voltage drop in cables and electrical isolation between system components.

Commissioning Process

Connection, Grounding, and Disconnection

Covers functional earth, line connection safety, and cable disconnection.

System Commissioning Steps

Outlines checks, interface configuration, testing, and network commissioning.

Parameterisation and Diagnostics

Parameterisation and Diagnostic Options

Explains parameter adaptation and lists diagnostic methods like LEDs and system checks.

Diagnostic Status and Messages

Details diagnostic status, message grouping, and specific diagnostic messages.

Load Voltage Monitoring

Describes load voltage monitoring and its diagnostic display.

Technical Data

General and Environmental Specifications

Provides general technical data, ambient conditions, and protection ratings.

Mechanical, Electrical, and UL Data

Details vibration, shock resistance, power supply, and UL certification data.

Summary

About This Document

Document Information

Covers applicable documents, product version, labelling, and specified standards.

Safety Guidelines

Safety Instructions, Intended Use, and UL Certification

Details safety rules, intended use, personnel qualifications, and UL certification.

Product Overview

Functionality and Structure

Describes the CPX-AP-I system, its function, structure, and variants.

Module Types

Details interface, input/output, and electrical interface modules with their functions.

LED Displays and Labelling

Explains LED displays for status and diagnostics, and module labelling elements.

System Communication and Assembly

System Communication and Addressing

Explains internal module communication, addressing, and data exchange.

Assembly and Mounting

Covers mounting distances, installation space, and direct mounting procedures.

Installation Procedures

Power Supply Concepts

Details power supply configurations, including logic and load supplies.

Voltage Drop and Electrical Isolation

Addresses voltage drop in cables and electrical isolation between system components.

Commissioning Process

Connection, Grounding, and Disconnection

Covers functional earth, line connection safety, and cable disconnection.

System Commissioning Steps

Outlines checks, interface configuration, testing, and network commissioning.

Parameterisation and Diagnostics

Parameterisation and Diagnostic Options

Explains parameter adaptation and lists diagnostic methods like LEDs and system checks.

Diagnostic Status and Messages

Details diagnostic status, message grouping, and specific diagnostic messages.

Load Voltage Monitoring

Describes load voltage monitoring and its diagnostic display.

Technical Data

General and Environmental Specifications

Provides general technical data, ambient conditions, and protection ratings.

Mechanical, Electrical, and UL Data

Details vibration, shock resistance, power supply, and UL certification data.

Festo CPX-AP-I Specifications

General IconGeneral
Product designationCPX-AP-I
Electrical isolationYes
Protection classIP65/IP67
Storage temperature-25 °C to +85 °C
Housing materialDie-cast aluminum
Number of digital inputs8
Nominal input voltage24 V DC
Input current at nominal voltage7 mA
Input delay time3 ms
Number of digital outputs8
Output functionPNP
Nominal output voltage24 V DC
Max. output current per channel0.5 A
Max. total current4 A
Short circuit strengthYes
Supply voltage24 V DC
Operating voltage range DC18 V ... 30 V
Current consumption at 24 V DC100 mA
Relative air humidity0 - 95 % (non-condensing)
Note on materialsRoHS compliant
Mounting typeVia through-hole
Switch-on threshold11 V DC
Switch-off threshold5 V
Current consumptionTypically 100 mA

Related product manuals