3
Electrical Configuration and Brewing Efficiency
US & Canada
Electrical Heater Voltage Maximum Batches per Hour*
Config. Code Configuration (AC) Phase Wires KW Amp draw 1.5L Batch 1.8L Batch
E15015 (1.5 ltr)
E18015 (1.8 ltr)
1 X 1500 watt 120 1 ph. 2 + ground 1.6 13.0 6.3 5.4
E15025 (1.5 ltr)
E18025 (1.8 ltr)
1 X 2100 watt 120 1 ph. 2 + ground 2.2 18.0 7.9 6.8
E15035 (1.5 ltr) 1 X 2700 watt 120/208 1 ph. 3 + ground 2.1 10.2 7.7 6.7
E18035 (1.8 ltr)
120/220 1 ph. 3 + ground 2.4 11.2 8.4 7.4
120/240 1 ph. 3 + ground 2.8 11.8 9.1 8.0
E15055 (1.5 ltr) 1 X 3700 watt 120/208 1 ph. 3 + ground 2.9 13.8 9.2 8.2
E18055 (1.8 ltr)
120/220 1 ph. 3 + ground 3.3 15.1 10.0 8.9
120/240 1 ph. 3 + ground 3.8 15.9 10.7 9.6
Export
Electrical Heater Voltage Maximum Batches per Hour*
Config. Code Configuration (AC) Phase Wires KW Amp draw 1.5L Batch 1.8L Batch
E15045 (1.5 ltr)
E18045 (1.8 ltr)
1 X 2700 watt 220 1 ph. 2 + ground 2.4 11.2 8.4 7.4
E15065 (1.5 ltr)
E18065 (1.8 ltr)
1 X 3700 watt 220 1 ph 2 + ground 3.3 15.1 10.0 8.9
Dimensions & Utility Connections