9
Programming
Batch Settings
Display
Turn the brewer off by pressing the power switch.
Press and hold the power switch until the display reads P r G. P r G
The left side STOP button will illuminate.
Quickly press the STOP button.
The display will show the software version. Example:
0.0 03.L
Press STOP to continue.
Batches are numbered 1 – 2 (single side) or 1 – 4 (dual side)
Next, the first batch parameter is displayed – batch 1, brew volume
1.1 1.00
Use the SCROLL UP and SCROLL DOWN buttons to adjust.
Press the STOP button to go to the next parameter – brew time. 1.2 4.00
Continue this way until all parameters are programmed for batch #1.
(See the chart below for an explanation of each parameter.)
Next, batch #2 programming begins.
2.0 OFF
Batches 2 and 4 may be disabled by leaving them set to “OFF”.
Change to “ON” to enable. Batches 1 and 3 cannot be disabled.
After all batches are programmed, go to temperature settings.
7 200
(See next page)
Important! After programming, you must press and hold the STOP button until the display reads STO to save the
settings and exit programming mode, or changes will be lost. You may exit programming at any time.
Batch Parameters
X=Batch Number (1 - 4)
Parameter Name Range Increment Default Setting Comment
X.0 Batch Enabled or
Disabled
On/Off Batch 1 & 3 = ON
Batch 2 & 4 = OFF
Batch 1 & 3 cannot
be disabled.
X.1 Brew Volume:
CBS-2031ee/2032ee 0.94 – 4.72 0.01 2.49 liters
CBS-2041ee/2042ee 0.25 – 1.25 0.01 1.0 gallons
To change setting to
liters or gallons, see
# 59 in Advanced
Settings section.
X.2 Brew Time (Min:Sec) 2:00 – 9:30 0:30 4:00 minutes
X.4 Prewet Percent 0.00 – 15.0% 1% 0 % Percentage of total
brew volume
X.5 Prewet Delay
(Min:Sec)
0:10 – 5:00 0:10 1:00 minute The time between
prewetting and start
of brew cycle.
X.6 Drip Delay (Min:Sec)
CBS-2031ee/2032ee 0:30 – 6:00 0:10 1:00 minute
CBS-2041ee/2042ee 0:30 – 6:00 0:10 1:30 minute
The time between
end of brew cycle
and unlocking of
brew basket.
1.1 1.00
PARAMETER
SETTING
BATCH #
Example: Left Side – Large Batch – Volume 1.0 Gal.