Console Problem & Countermeasure
Problem Countermeasures
The Login prompt does not appear,
even after turning the power on.
Ensure that the console terminal's communication
settings are correct. Setting values: 9600 bits/s; 8-bit
characters; 1 stop bit; no parity; no flow control; RS
and ER always on.
Ensure that the console terminal's communication
settings are correct. Setting values: 9600 bits/s; 8-bit
characters; 1 stop bit; no parity; no flow control; RS
and ER always on.
Ensure that the connection at the FR8000-OLS
CONSOLE port is normal.
Confirm that the FR8000-OLS POWER LED is lit and
that FAULT LED is not lit.
Setting values have not been input
normally.
If the setting consists of normal alphanumeric
characters, this problem may be result of a
malfunction in the FR8000-OLS internal memory.
Please contact the store or dealer where you made
your purchase.
SNMP Manager Problem and Countermeasures
Problem Countermeasures
Cannot access the FR8000-OLS from
the SNMP manager.
Ensure that the FR8000-OLS’s IP address, subnet
mask, and default router setting are correct. If the
setting is fixed, confirm that they are correct after
first resetting the device once again or turning it
off and then back on.
Ensure that the correct IP address has been
registered fro the SNMP manager.
Ensure that the community names for the SNMP
the SNMP manager and the FR8000-OLS are
identical.