The SNMP cannot receive traps
Ensure that the IP address to which traps are being
sent has been properly set in the FR8000-OLS
TELNET Problem & Countermeasures
Problem Countermeasures
Login to the FR8000-OLS is not
possible from a terminal
Ensure that the FR8000-OLS IP address, subnet mask,
and default router settings are correct. If settings are
fixed, confirm that they are correct after first resetting the
device once again or turning it off and then back on.
Ensure that the communication setting for the connected
port has been enabled. If so, examine the cable
connection.
Ensure that the address to which you are attempting to
TELNET is indeed the FR8000-OLS address.
Ensure that the FR8000-OLS has started up and is
functioning normally.
Ensure that TELNET access has not been limited using
telnet mode and TELNET IP commands.