SWIMMING POOL PUMPS
INSTRUCTION MANUAL
FP SERIES PUMPS
1

Questions and Answers

Summary

Important Safety Instructions

General

Overview of pump suitability and operating conditions.

Installation Guidelines

Instructions for horizontal installation, pipe placement, and electrical safety.

Pipe Assembly

Instructions for connecting pipes to avoid stress on the pump.

Electrical Connection

Requirements for wiring, breaker size, and bonding according to codes.

Controls Prior to Initial Start-Up

Checks before powering on the pump, including shaft rotation and voltage.

Operation and Troubleshooting

Start-Up Procedure

Steps for starting the pump and checking water flow.

Maintenance and Winterization

Guidance on pump maintenance and preparing for winter.

Trouble Shooting Guide

Common pump issues, possible causes, and checks.

Technical Specifications and Diagrams

Performance Curve

Graphical representation of pump performance across different models.

Installation Diagram

Visual guide showing how to connect the pump in a system.

Pump Dimensions

Physical dimensions of the pump in millimeters.

Fibropool Warranty

Warranty Coverage Details

Specifics on what is covered, duration, and exclusions.

Warranty Registration

Instructions for registering the product to claim warranty.

Overview

The provided document is an instruction manual for FIBROPOOL SWIMMING POOL PUMPS, specifically the FP Series. It covers important safety instructions, installation, operation, maintenance, troubleshooting, and technical specifications.

Function Description:

The FIBROPOOL FP Series pumps are single-stage centrifugal pumps designed for use with various pool equipment. Their primary function is to circulate water for filtration and other pool maintenance tasks. They are compatible with both chlorine and salt water systems.

Important Technical Specifications:

The manual provides a performance curve and a table of specifications for different models within the FP Series.

  • Maximum Operating Water Temperature: 120°F
  • Electrical Connection: Must be permanently connected to fixed wiring. Ground and Bonding must BOTH be connected. The electrical system must comply with local building and electrical codes. A service disconnect is required within reach of the unit. Equipotential bonding between the pool and the pump must be made using a BARE Copper Wire, #8 or thicker.
  • Voltage: The pumps are designed for 240 VAC, though the Fp75(T) model is listed with 120 VAC.
  • Frequency: 60 Hz for all listed models.
  • Power (P1): Ranges from 0.55 kW (0.75 Hp) for the Fp75(T) to 2.2 kW (3 Hp) for the Fp300(T).
  • Flow Rate (GPM): Ranges from 75 GPM for the Fp75(T) to 145 GPM for the Fp300(T).
  • Head (ft): Ranges from 40 ft for the Fp75(T) to 72 ft for the Fp300(T).
  • Dimensions (in millimeters):
    • Overall length (L): Approximately 302 mm (motor side) + 200 mm (pump body) = 502 mm.
    • Height: Approximately 314 mm (pump body) and 234 mm (motor side).
    • Width: Approximately 276 mm (pump body) and 253 mm (motor side).
    • Port connections are threaded for UNIONS, and supplied adapters should be used.

Usage Features:

  • Installation:
    • Should be installed horizontally.
    • The suction pipe of the pump should be as short as possible.
    • The rating label must be visible after installation.
    • Included fittings are designed to seal once installed; hand tighten and then turn ¼ turn with water pump pliers.
    • The suction and discharge pipes should not put any stress on the pump.
  • Start-Up:
    • Before initial start-up, verify the pump shaft turns freely and check that the mains voltage and frequency match the nameplate.
    • Prime the pump with pool water by filling the strainer pot.
    • The pump should NEVER operate dry.
    • After turning on the pump switch, observe water flow within 30 seconds. If no flow, turn off the pump, re-prime, and try again. After 3 attempts without flow, check for clogs or air leaks on the suction side.
  • Compatibility: Designed to operate with sand filters, cartridge filters, mod media filters, and DE filters.

Maintenance Features:

  • General Maintenance: The pumps do not require special maintenance or programming.
  • Winterization: If the pump is to be winterized, it is recommended to disassemble, clean, and store it in a dry, well-ventilated place. If this is not practical, ensure all water is drained from the pump.
  • Troubleshooting Guide: The manual includes a troubleshooting section to address common issues:
    • Pump Does Not Turn: Check incoming power, circuit breaker, and if the capacitor is swollen or burst. Also, check if the motor shaft is free from obstructions (fan blade, impeller).
    • Pump Not Pumping Properly: Check if unions are tight and O-rings are in place, if suction (skimmer or main drain cover) is blocked, if the pump basket or impeller is clean, and if there is a leak in piping or the pump.
    • Low Voltage: Check if the proper voltage is applied and if an extension cord is being used.

Warranty Information:

The product comes with a FIBROPOOL WARRANTY.

  • Pumps (AT, SB, SS, SC series):
    • Motors: 1 year
    • Shaft seals: 1 season (Note 2)
    • Plastic components: 1 year full, 2-3 years prorated (Note 1)
    • Basket: 1 year (Note 2)
    • No labor coverage.
  • Warranty Coverage Begins: On the date of installation if installed by a licensed/competent professional, or on the day of sale if installed by the end user.
  • Proof of Purchase: Required for warranty coverage.
  • Prorated Warranty: Some components have prorated warranties (e.g., 10 years decreasing by 10% per year, or 3 years decreasing by 33.33% per year).
  • Limitations: Warranty applies only to the original purchaser and is non-transferable. Fibropool has the option to repair or replace defective items. Purchaser is responsible for shipping costs to and from the warranty/repair center.
  • Exclusions: Freeze expansion damage (Note 1), chemical corrosion from improper maintenance (Note 2), and scuff/rip/tear/overexposure to UV rays (Note 4) are not covered. Seasonal warranty begins on the purchase date and ends on December 31st of the same year (Note 3).
  • FIBROPOOL is not responsible for consequential, incidental, or contingent damages.

FibroPool FP Series Specifications

General IconGeneral
BrandFibroPool
ModelFP Series
CategoryWater Pump
LanguageEnglish