terminals)
Prime pump with pool water, by filling the strainer pot.
THE PUMP SHOULD NEVER OPERATE DRY.
6.Start-Up
Turn on the pump switch, and observe the water flow within 30 seconds. If there is no water flow
visible within 30 seconds, turn off the pump and Prime with pool water ( fill the strainer pot with pool
water) again. After 3 attempts, if there is no water flow, there must be a clog in the pipes, or an air leak
on the the suction side.
7.Maintenance and Winterization
Our pumps do not require any special maintenance or programming.
If the pump will be Winterized, it is recommended to disassemble, clean and store it in a dry, well-
ventilated place. If this is not practicle, please be sure to drain all the water from the pump
8.Trouble Shooting Guide
SYMPTON POSSIBLE CAUSE CHECK
PUMP DOES
NO TURN
NO POWER
TO PUMP
Incoming power to the pump
Is circuit breaker on?
Is the capacitor swollen, or burst open?
MOTOR HUMMING
BUT NOT TURNING
Is the motor shaft free? Check for obstructions
to the motor fan blade, or impeller.
PUMP NOT
PUMPING
PROPERLY
BLOCKAGE OR
LEAK
Are the unions on tight and o rings in place?
Is the suction (skimmer or Main Drain cover)
blocked??
Is the pump basket clean?
Is the pumps impeller clean?
Is there a leak in piping or the pump?
LOW VOLTAGE
Is the proper voltage applied to the pump?
Is there an extension cord being used?
3