Page 6
SWG-4A ARMSTRONG SIDEWALL POWER VENTING KIT
Field Controls P/N 46205407
Kit Includes:
SWGII-4HD Sidewall Power Venter
CK-43F Control Kit
Includes: 4" MG-1 Barometric Draft Control
Fan Proving Switch
Fixed post purge
For use with Armstrong furnace models that begin with the following:
AMEG6G EG5G EG6G EG7G EG8G GCJ GHJ GUJ
Furnace Configuration and Vent Pipe Restrictions
Model
Number
Configuration Furnace Vent
Collar Diameter
(in.)
Max. Equivalent Vent
Length (ft.); 4" Diameter
Vent Pipe
AMEG6G Upflow 4 60
EG5G Lowboy 4 60
EG6G Upflow 4 60
EG7G Downflow 4 60
EG8G Horizontal 4 41
GCJ Downflow-Horizontal 4 60
GHJ Upflow-Horizontal 4 60
GUJ Upflow 4 60
General Wiring
For complete installation information refer to the Field Controls SWG-4A Power Venter Installation
Manual for details (P/N 46333500.)