6
FUNCTION
The Filtreau Combi PF20 is a low-maintenance lter system that provides healthy, clear water, without the user
having to perform daily maintenance.
The drum lter, combined with the 250L moving-bed bio-chamber, makes the lter suitable for (koi) ponds up to as
much as 35,000L!
The system is tted as standard with one inlet (110mm) and two outlets (110mm). A water ow of more than 20m3/h
can be achieved with this system!
WARNING! Read the entire manual before use/installation of the system!
SAFETY AND INSTALLATION REQUIREMENTS
See Technical specications for the required mains voltage and current type.
The device may only be connected to an electrical installation that meets the legal standards. A residual-current
device (30 mA) and earthed wall socket are required. If in doubt, consult a qualied installer.
Both the Drum Filter and the control box must be installed in a dry, sheltered place. Not in direct sunlight.
Keep the power plug free from moisture. Prevent water from running along the power lead into the socket.
(See gure 1 for looping of the power lead).
The device is suitable for fresh water.
The device is suitable for water temperatures of 4 to 40 °C. If exposed to temperatures outside these limits,
the device must be fully isolated from the water circuit.
Before commissioning, check the entire device, mains lead and plug for damage. If damage is found,
the device may not be used. Have the damage assessed by the dealer.
The device may only be switched on when there is sucient water ow.
When opening the lid/maintenance cover the power to the device/control box must always be switched o.
Warning! The UV-C lamp may still be hot up to ten minutes aer it is switched o.
INSTALLING HIGH PRESSURE PUMP; SEE FIGURE 1
It is important, however, that high-pressure PVC is used for this purpose. The pump generates a pressure of 3 bar.
Pressure peaks of 4 bar may occur during start-up. Therefore do not use sewer & drain PVC.
The high-pressure pump itself must be placed in a moisture-free location below the water level.
Never place the high pressure pump directly on the lter oor.
TIP: Place a ball valve between the output (A1) and the high pressure pump (B).
1. Place a tee at the lter outlet (A). Outlet (A1) of the tee is for the high pressure pump (B); always have this outlet
(A1) pointing down so that water always ows into the high pressure pump.
The other one (C) is used as a return to the pond.
2. Connect the line from the output (A) of the tee to the high-pressure pump (B) and then connect the piping of the
high pressure pump (B) to the spray tube (C).