PG 1
Operation Guide 3M-50
To turn your 3M-50 ON, press the MODE button on the right side.
This cycles the 3M-50 through HEAT, COOL, AUTO and OFF modes.
The 3M-50 programmable communicating
thermostat operates via a high-quality, easy-to-
use touch screen. To program or adjust your 3M-
50, simply touch your nger rmly to the screen.
The screen will automatically light up and you will
hear a “beep.” The screen will respond differently
to different types of touches, so you may want to
experiment by touching it different ways, nger,
ngernail, etc. Do not use a sharp or metallic
device; it will scratch the screen.
ENGLISH
Statement of use: 100% Compatible with all popular
residential HVAC systems; 24VAC single, two stage
conventional heating systems (gas/oil/electric), heat
pumps, single stage or with auxiliary heat (electric
or fossil), zoned forced air and zoned hot water (2
or 3 wire), millivolt systems (with a 12-24 AC or DC
source), one or two stage cooling, and hybrid systems.
Save
Energy
button
Power Grid
status
indicator
top cover
Touch screen
Wire
terminals
Mode
button
Fan
button
MENU
n
PROG
butto
Reset
button
HVAC
selection
switches
bottom
cover
D
A
Y
F
LINK
RADIO
TARGET
TEMP
1
COOL
A
U
TO
P
M
n
butto
1005-011-001

Other manuals for Filtrete 3M-50

Question and Answer IconNeed help?

Do you have a question about the Filtrete 3M-50 and is the answer not in the manual?

Filtrete 3M-50 Specifications

General IconGeneral
BrandFiltrete
Model3M-50
CategoryThermostat
LanguageEnglish

Summary

Operation Guide 3M-50

Statement of Use

Details compatibility with various residential HVAC systems, including conventional, heat pumps, and zoned systems.

Control Screens Overview

HOME Screen

The basic screen displayed during operation, accessible by touching the HOME icon.

MENU Screen Functions

Set Time

Allows adjustment of the current time of day using touch arrows for navigation.

Set Day

Enables setting the current day of the week by cycling through options.

Set °C -°F Display

Touch to change temperature display units between Fahrenheit and Celsius.

Lock Program

Touch for 5 seconds to lock or unlock program settings on the thermostat.

PROGRAM Screen

Set Time Slot

Select the desired time slot (MORN, DAY, EVEN, NITE) for programming.

Set Program Time

Adjust the start time for each programmed time period.

Copy Program

Copy current day's program to the next day or all days.

MANUAL Screen Functions

Temporary Override

Allows temporary adjustment of the target temperature for the current time slot only.

HOLD Function

Holds the set temperature indefinitely until manually cancelled, bypassing the program.

HOLIDAY Program

Sets a repeating program for holidays, superseding the weekly schedule.

Simple HOME Screen

Initial Settings

Set Day of the Week

Cycle through days to select the current day of the week.

Set Time of Day

Adjust the current time using forward/backward arrows, with fast set option.

Set Audible Chirp

Toggle the audible chirp sound on or off by touching the musical note icon.

Auto-Run Program

To Change the Program

Instructions to access the PROGRAM screen to modify the default settings.

PROGRAM Screen Details

Select Time Slot

Choose the period (MORN, DAY, EVEN, NITE) to program.

Select Start Time

Set the desired starting time for the selected time slot.

Select Target Temperature

Adjust the desired temperature for the selected time slot using +/- arrows.

MENU Screen Functions

TIME of DAY

Set the current time using left/right arrows with fast set option.

SWING (HVAC cycling rate)

Set temperature variance for HVAC cycling, from 0.5° to 2.0°F.

MENU Screen Functions (cont.)

Chirp Set

Toggle the audible chirp sound on or off.

°F Set

Change the temperature display scale from Fahrenheit to Celsius.

FILTER - Air Filter Alert

Program alerts for HVAC air filter changes, setting usage limit.

LOCK Function

Set thermostat to partial or full lock mode to restrict user access.

MENU Screen Functions (cont.)

CALIBRATE

Adjust the displayed temperature to match another thermostat or preference.

DIFF (Differential)

Set the temperature differential for 2nd stage heating/cooling.

MANUAL Screen Functions

TEMPORARY Override

Temporarily change target temperature for the current time slot only.

HOLD Function

Hold the current target temperature indefinitely, bypassing programmed schedules.

HOLIDAY Program

Set a repeating holiday schedule that overrides the weekly program.

MANUAL Screen Functions (cont.)

EMER (Emergency Heat)

Engages auxiliary heat for heat pump systems when primary is insufficient or defective.

Save Energy Button

Adjusts target temperature by 4°F in COOL or HEAT for energy savings.

Mode and Fan Control

MODE Button

Cycles through HEAT, COOL, AUTO, and OFF modes.

FAN Button

Controls fan operation, switching between AUTO and manual ON.

Simple Screen Access

Hold PROGRAM for 12 seconds to access a limited display mode.

System Features and Connectivity

RESET Button

Reboots the 3M-50 processor without affecting stored user programs.

Compressor Protection

Ensures a 4-minute minimum cycle time for compressor protection.

Using USNAP Radios

Connects the thermostat to a home WiFi network for remote access and energy management.

Caution

Warning against inserting or removing USNAP modules while power is ON.