5.Rated technical data
Descriptions Unit ICOOL 2.3 IWARM 2.3
Cooling capacity W (Btu/h) 2360 (8050) 2360 (8050)
Heating capacity W (Btu/h) 2()2()
Rated voltage V 230 230
Frequency Hz 50 50
Electrical heater W (Btu/h) ------- 1600 (5500)
Absorbed power in cooling W 904 904
Absorbed current in coolin
g
A
3.9 3.9
g
Absorbed power in heating W  
Absorbed current in heating A
 4
EER label ( Cooling Mode ) ABCDEFG
AA
COP lable ( Heating Mode ) ABCDEFG A
A
Indoor Air low m3/h 350 350
Outdoor Air low
m3/h
450
450
Outdoor
Air
low
m3/h
450
450
Noise lever ( SPL ) dB(A) 49 49
Dehumidification capacity L/24h 12.5 12.5
Optional temperature (remote
control)
ć
18-30 18-30
Maximum external temperature ***
e
C 43 43
Minimum external temperature HP
e
C
5
5
Minimum
external
temperature
HP
****
e
C
-
5
-
5
Fuse (T3,15L) V 250 250
Refrigerant / R410a g 640 640
Dimension H/W/D cm 43/95.5/19.5 43/102/19.5
Net Weight Kg 40 42
**The above data could be changed in order to improve the performance.
*** The machine can work at T3 condition , with max out door temperature 52
e C but the cooling performance will be reduced .
**** The machine can work at -15 eC , but the Heating performance will be
reduced .

Related product manuals